# Compressor breakdown in the plant: what to do first

**The plant compressor has broken down: what should the maintenance team do first?**

In its 2016 sourcebook, the US Department of Energy set out how to stop a compressor for service: disconnect and lock out the main power, isolate the compressor from the air supply, depressurise it completely, and never assume a stopped compressor is safe, because it could restart at any time.

## Make the machine safe

The third edition of the US Department of Energy (DOE) sourcebook, Improving Compressed Air System Performance (2016), listed these steps for stopping a compressor for maintenance or service, citing OSHA regulation 1910.147 on lockout/tagout, and told readers to give preference to the manufacturer's manuals over its typical procedures:

1. Disconnect and lock out the main power source, with a sign at the main power disconnect switch saying the compressor is being serviced.
2. Isolate the compressor from the compressed air supply by closing a manual shutoff valve downstream, and upstream in booster service, with a sign at the valve. A pressure relief valve should be installed upstream of any isolation valve.
3. Lock open a pressure relief valve so the system can be completely depressurised. The sourcebook warned never to remove a plug to relieve the pressure.
4. On water-cooled compressors, shut off the cooling water supply, and open all manual drain valves in the area to be serviced.
5. Wait for the unit to cool before starting to service.

In Europe, the EU-OSHA OSHwiki guidance on maintenance (updated June 2024) tells employers to develop and apply safe systems of work, including permits to work and lock-out tag-out procedures, and to make sure machines have a stop mechanism or isolation switch for maintenance. The OSHwiki page on why maintenance is a high-risk activity adds that the unforeseen nature of remedial maintenance makes it a high-risk activity, especially under time pressure, as in a breakdown.

## Record what the machine shows

The 2016 sourcebook recommended recording all observations and meter readings for compressors, dryers and filters, and said control panel data, frequent inspections and log sheets were required to avoid unscheduled system shutdowns. Its section on lubricant-free rotary screw compressors added that previous records are very helpful in judging whether readings are normal. The Compressed Air Challenge Fact Sheet #5 (May 2026) says most problems are minor and can be corrected by simple adjustments, cleaning, part replacement or the elimination of adverse conditions.

## Keep compressed air available

The Compressed Air Challenge Fact Sheet #11 (May 2026) says storage can also help systems ride through a compressor failure or short energy outages.

For Ultra Controlo equipment, UltraCare provides preventive and corrective maintenance, original spare parts and emergency support; Ultra Controlo also distributes and services Gardner Denver, Elmo Rietschle and Thomas in Portugal.

### Is a stopped compressor safe to work on?

The 2016 DOE sourcebook warned never to assume a compressor is safe to work on just because it is not operating, because it could restart at any time.

### Whose instructions come first?

The DOE sourcebook told readers to refer and give preference to the manufacturer's manuals over its typical maintenance procedures.

## Sources

- [US Department of Energy, Improving Compressed Air System Performance: A Sourcebook for Industry, third edition (2016)](https://www.energy.gov/sites/prod/files/2016/03/f30/Improving%20Compressed%20Air%20Sourcebook%20version%203.pdf)
- [EU-OSHA, OSHwiki: What do employers have to consider regarding maintenance? (updated 15 June 2024)](https://oshwiki.osha.europa.eu/en/themes/what-do-employers-have-consider-regarding-maintenance)
- [EU-OSHA, OSHwiki: Why is maintenance a high risk activity? (updated 15 June 2024)](https://oshwiki.osha.europa.eu/en/themes/why-maintenance-high-risk-activity)
- [Compressed Air Challenge, Fact Sheet #5: Maintenance of Compressed Air Systems for Peak Performance (May 2026, Rev. 1)](https://www.compressedairchallenge.org/data/sites/1/media/library/factsheets2026/fact-sheet-5-maintenance-of-compressed-air-systems-for-peak-performance_updated2026.pdf)
- [Compressed Air Challenge, Fact Sheet #11: Proven Opportunities at the Component Level (May 2026, Rev. 01)](https://www.compressedairchallenge.org/data/sites/1/media/library/factsheets2026/fact-sheet-11-proven-opportunities-at-the-component-level_updated2026.pdf)
- [Ultra Controlo, UltraCare technical assistance centre](https://www.ultracontrolo.com/technical-assistance-center)
- Ultra Controlo, Industrial 2026 catalogue, p. 10 (partner brands)

Reviewed: 2026-11-19. Ultra Controlo engineering. https://library.ultracontrolo.com/answers/emergency-compressor-breakdown-what-to-do/