# How working pressure changes screw compressor output

**How does working pressure change the output of a screw compressor?**

In the ULTRAAR ME datasheet (2026), every ULTRASCREW fixed speed model listed at both 10 and 13 bar has a lower capacity at 13 bar, for example ULTRASCREW 37 FSD with 322 Nm³/h at 10 bar and 265 Nm³/h at 13 bar.

In the ULTRAAR ME datasheet (2026), as published on the ULTRASCREW page of ultracontrolo.com, each fixed speed ULTRASCREW is listed with a capacity per compressor at 10 bar and, from ULTRASCREW 7 FSD to ULTRASCREW 110 FSD, a second capacity at 13 bar. For every model listed at both pressures, the figure at 13 bar is lower than at 10 bar.

| Model | kW | 10 bar, Nm³/h | 13 bar, Nm³/h |
|---|---|---|---|
| ULTRASCREW 7 FSD | 7.5 | 52 | 38 |
| ULTRASCREW 11 FSD | 11 | 81 | 67 |
| ULTRASCREW 15 FSD | 15 | 123 | 89 |
| ULTRASCREW 18 FSD | 18.5 | 149 | 124 |
| ULTRASCREW 22 FSD | 22 | 182 | 152 |
| ULTRASCREW 30 FSD | 30 | 284 | 235 |
| ULTRASCREW 37 FSD | 37 | 322 | 265 |
| ULTRASCREW 45 FSD | 45 | 405 | 314 |
| ULTRASCREW 55 FSD | 55 | 508 | 408 |
| ULTRASCREW 75 FSD | 75 | 664 | 554 |
| ULTRASCREW 90 FSD | 90 | 810 | 660 |
| ULTRASCREW 110 FSD | 110 | 990 | 840 |

ULTRASCREW 4 FSD (4 kW, 22 Nm³/h), ULTRASCREW 5 FSD (5.5 kW, 34 Nm³/h) and ULTRASCREW 132 FSD (132 kW, 1,170 Nm³/h) are listed at 10 bar only. The values are capacity per compressor, as listed in the datasheet; no capacity is listed for pressures between 10 and 13 bar.

## What the Compressed Air Challenge recommends

Fact Sheet #4 (May 2026) says equipment should be specified and operated at the lowest efficient operating pressure, and to check with the compressor manufacturer for performance specifications at different discharge pressures. Increasing the compressor discharge pressure or adding compressor capacity results in significant increases in energy consumption.

Fact Sheet #1 says the required pressure level must take into account system losses from dryers, separators, filters and piping, and gives a rule of thumb: every 2 psi increase in operating pressure requires an additional 1% in operating energy costs. Fact Sheet #4 gives 7 psid as a typical pressure differential for a filter, pressure regulator and hose. See [why pressure drop costs energy](https://library.ultracontrolo.com/answers/why-does-pressure-drop-cost-energy/).

## Variable speed version

The variable speed ULTRASCREW operates at constant output pressure over a range of 5 to 14 bar, with a smooth start, according to the product page. The ULTRAOX ST datasheet (2026) lists the variable speed compressors at 10 bar. See [ULTRASCREW FSD, VSD and DS VSD compared](https://library.ultracontrolo.com/answers/ultrascrew-fsd-vs-vsd-vs-ds-vsd/) and [how an industrial air compressor is sized](https://library.ultracontrolo.com/answers/how-is-an-industrial-air-compressor-sized/).

### Should I choose 10 bar or 13 bar?

Fact Sheet #4 says equipment should be specified and operated at the lowest efficient operating pressure, and that the compressor manufacturer should be asked for performance specifications at different discharge pressures. Fact Sheet #1 adds that the required pressure must include losses from dryers, separators, filters and piping.

### Does a higher working pressure cost more energy?

Fact Sheet #1 gives a rule of thumb: every 2 psi increase in operating pressure requires an additional 1% in operating energy costs.

## Sources

- [ULTRASCREW product page, ultracontrolo.com (checked 18 November 2026)](https://www.ultracontrolo.com/products/ultrascrew)
- [ULTRAAR ME datasheet (2026), configuration table](https://www.ultracontrolo.com/products/ultraar-me)
- [ULTRAOX ST datasheet (2026), configuration table](https://www.ultracontrolo.com/products/ultraox-st)
- [Compressed Air Challenge, Compressed Air Systems Fact Sheet #4: Pressure Drop and Controlling System Pressure (May 2026, Rev. 1)](https://www.compressedairchallenge.org/data/sites/1/media/library/factsheets2026/fact-sheet-4-pressure-drop-and-controlling-system-pressure_updated2026.pdf)
- [Compressed Air Challenge, Compressed Air Systems Fact Sheet #1: Assessing Compressed Air Needs (May 2026, Rev. 1)](https://www.compressedairchallenge.org/data/sites/1/media/library/factsheets2026/fact-sheet-1-assessing-compressed-air-needs_updated2026.pdf)

Reviewed: 2026-11-18. Ultra Controlo engineering. https://library.ultracontrolo.com/answers/how-does-working-pressure-change-screw-compressor-output/