# How is air compressor efficiency compared?

**How do you compare the energy efficiency of two air compressors?**

Compressed Air Challenge Fact Sheet #8 (May 2026) says two air compressors are compared on data sheets tested to the same standard, at the same conditions and reported consistently, using bhp or total kW input per acfm, not the motor nameplate, and part-load efficiency as well as full load.

Fact Sheet #8 says evaluating and comparing industrial air compressor capacities and efficiencies can be a daunting task, because standards exist for testing performance but have not always been applied consistently, and test results are not always published in a consistent format. Buyers should therefore make sure the compressors have been tested using the same standard, at the same conditions, and that the data is reported in a consistent manner.

## The standard and the data sheet

For displacement compressors, including rotary screw compressors, the fact sheet names ISO 1217, Displacement Compressors Acceptance Tests, as the recognized performance standard, and says it is too complex for performance testing in volume production. CAGI, the Compressed Air and Gas Institute, and Pneurop developed Simplified Test Codes, and CAGI members publish the performance of their products on data sheets based on them. Besides Package Specific Power, the data sheets have been revised to include Isentropic Efficiency for some types of rotary compressors.

The industry norm for comparison is bhp per 100 acfm at a compressor discharge pressure of 100 psig. A typical single-stage lubricant-injected rotary screw compressor has a rating of approximately 22 bhp/100 acfm, referenced to standard inlet conditions, and performance at site conditions will differ from test data because of ambient temperature, pressure and humidity.

## Checks for a like-for-like comparison

- Same standard, same conditions: standard conditions should be 14.5 psia (1 bar), 68 °F (20 °C) and dry, at 0% relative humidity.
- Use the bhp rating, not the motor nameplate hp rating. The full-load power of a typical package exceeds the nominal motor rating.
- To include the motor efficiency and all package accessories and losses, use a rating in total kW input per acfm.
- A flange-to-flange rating leaves out inlet, discharge and other package losses, which can affect overall efficiency by 5% or more.
- Energy use of accessories, such as cooling fan motors, may not be treated consistently, and manufacturers may apply ranges or tolerances to performance data.
- Compare part-load efficiencies as well, because most systems operate at part load much of the time, although the variety of control methods can make this difficult.

The 2016 DOE sourcebook adds that two-stage rotary screw compressors are generally more efficient than single-stage units.

## What the ULTRASCREW datasheet states

The ULTRASCREW datasheet states that air flow is measured in accordance with ISO 1217:2009, Annex C, and that its values refer to 1 bar absolute, 0% relative humidity, 20 °C inlet air temperature and a 71 °C thermostatic valve value. The datasheet used for this page does not state package specific power or isentropic efficiency, so this page gives none; ask the supplier for it on the same basis as for any other compressor. See [the ULTRASCREW range](https://library.ultracontrolo.com/products/ultrascrew/), [free air delivery](https://library.ultracontrolo.com/glossary/free-air-delivery/) and [normal cubic metres](https://library.ultracontrolo.com/glossary/normal-cubic-metre/).

### Why not compare the motor nameplate power of two compressors?

Fact Sheet #8 says the actual full-load power of a typical package exceeds the nominal motor rating, so the bhp rating should be used, or a total kW input per acfm rating to include motor efficiency and package accessories and losses.

### Which standard is used for rotary screw compressor performance?

Fact Sheet #8 names ISO 1217, Displacement Compressors Acceptance Tests, as the recognized performance standard for displacement compressors, including rotary screw compressors. The ULTRASCREW datasheet states that air flow is measured in accordance with ISO 1217:2009, Annex C.

## Sources

- [Compressed Air Challenge, Compressed Air Systems Fact Sheet #8: Packaged Compressor Efficiency Ratings (May 2026, Rev. 1)](https://www.compressedairchallenge.org/data/sites/1/media/library/factsheets2026/fact-sheet-8-packaged-compressor-efficiency-ratings_updated2026.pdf)
- [US Department of Energy and Compressed Air Challenge, Improving Compressed Air System Performance: A Sourcebook for Industry, third edition (2016), chapter 2](https://www.energy.gov/sites/prod/files/2016/03/f30/Improving%20Compressed%20Air%20Sourcebook%20version%203.pdf)
- [ULTRASCREW datasheet, p. 3](https://www.ultracontrolo.com/products/ultrascrew)

Reviewed: 2026-11-18. Ultra Controlo engineering. https://library.ultracontrolo.com/answers/how-is-air-compressor-efficiency-compared/