# What should a compressor tender specify?

**What should a tender for an industrial air compressor specify?**

A compressor tender can draw its content from the Compressed Air Challenge fact sheets (May 2026): end-use air quality, quantity and pressure (Fact Sheet #1), performance tested to one standard, such as ISO 1217, at the same conditions, with part-load efficiency and package input power (#8), and life-cycle cost, not the lowest bid (#9).

## 1. The duty

Fact Sheet #1 (May 2026, Rev. 1) defines compressed air needs by the air quality, quantity and level of pressure required by the end uses. The total air requirement is the sum of the average air consumption of each tool and process, not of their maximums, and required pressure levels must take into account losses from dryers, separators, filters and piping. Air quality can be stated as ISO 8573-1:2010 purity classes, which cover particles, water and oil ([ISO 8573-1](https://library.ultracontrolo.com/standards/iso-8573-1/)); sizing is covered in [how an industrial air compressor is sized](https://library.ultracontrolo.com/answers/how-is-an-industrial-air-compressor-sized/).

## 2. Performance on a common basis

Fact Sheet #8 (May 2026) notes that purchasers can find it difficult to compare equipment performance, and that for displacement compressors, including rotary screw machines, ISO 1217 is the recognized performance standard; ISO 1217:2009 specifies acceptance test methods for volume rate of flow and power requirements. Users should make sure compressors were tested to the same standard and at the same conditions, with standard conditions of 1 bar, 20°C and dry air. The fact sheet also lists the usual traps:

- The full-load power of a package exceeds the motor nameplate rating: motors usually have a 15% service factor and most manufacturers use up to two thirds of it, so full-load power will be 10% above the nominal rating.
- A rating in total kW input per acfm includes the motor efficiency and all package accessories and losses.
- Flange-to-flange ratings leave out inlet, discharge and other package losses, which can affect overall efficiency by 5% or more.
- Energy for accessories such as cooling fan motors may not be treated consistently, and manufacturers may apply ranges or tolerances to performance data.
- Most systems operate at part load much of the time, so part-load efficiencies should be compared too.

## 3. Controls

Fact Sheet #6 (May 2026) says the type of controls is largely determined by the type of compressor and the facility's demand profile ([when a variable speed compressor makes sense](https://library.ultracontrolo.com/answers/when-does-a-variable-speed-compressor-make-sense/)).

## 4. Life-cycle cost

Fact Sheet #9 (May 2026) warns that too often users are only concerned with initial cost and accept the lowest bid, ignoring system efficiency, and says users should select equipment based on life-cycle economics ([the cost of compressed air](https://library.ultracontrolo.com/answers/what-is-the-cost-of-compressed-air-per-cubic-metre/)).

## What buyers have asked for

Buyers add their own conditions. In a 2026 international tender notice in Cameroon, with bids due by 13 May 2026 (closed), for two enclosed 37 kW screw compressors with two dryers, SODECOTON listed among its elimination criteria the absence of a prospectus, catalogue, drawing or datasheet produced by the manufacturer and non-compliance with the full set of technical specifications, and among its essential criteria the warranty period and the after-sales service, meaning the availability of spare parts. In June 2014, for a minor contract (contrato menor), the Zaragoza city council's drinking water plant specified a variable speed lubricated screw compressor with a permanent magnet motor at IE4 efficiency level, no belt or gear coupling, an integrated speed drive holding 7 bar at the outlet with flow between 15 and 60 litres per second, and a noise level below 64 dB.

For example, the ULTRASCREW datasheet states that its air flow is measured in accordance with ISO 1217:2009, Annex C, with values at 1 bar absolute, 0% relative humidity and 20 °C inlet air temperature.

### Why ask for ISO 1217 test data?

Fact Sheet #8 (May 2026) calls ISO 1217 the recognized performance standard for displacement compressors and says compressors being compared should be tested to the same standard, at the same conditions.

### Is the motor nameplate power the compressor's input power?

No. Fact Sheet #8 (May 2026) says the full-load power of a typical package exceeds the motor nameplate rating, and recommends a rating in total kW input per acfm to include motor efficiency and package losses.

## Sources

- [Compressed Air Challenge, Compressed Air Systems Fact Sheet #1: Assessing Compressed Air Needs (May 2026, Rev. 1)](https://www.compressedairchallenge.org/data/sites/1/media/library/factsheets2026/fact-sheet-1-assessing-compressed-air-needs_updated2026.pdf)
- [Compressed Air Challenge, Compressed Air Systems Fact Sheet #6: Compressed Air System Controls (May 2026, Rev. 1)](https://www.compressedairchallenge.org/data/sites/1/media/library/factsheets2026/fact-sheet-6-compressed-air-system-controls_updated2026.pdf)
- [Compressed Air Challenge, Compressed Air Systems Fact Sheet #8: Packaged Compressor Efficiency Ratings (May 2026, Rev. 1)](https://www.compressedairchallenge.org/data/sites/1/media/library/factsheets2026/fact-sheet-8-packaged-compressor-efficiency-ratings_updated2026.pdf)
- [Compressed Air Challenge, Compressed Air Systems Fact Sheet #9: Compressed Air System Economics (May 2026, Rev. 1)](https://www.compressedairchallenge.org/data/sites/1/media/library/factsheets2026/fact-sheet-9-compressed-air-system-economics_updated2026.pdf)
- [EVS (Estonian Centre for Standardisation), ISO 1217:2009 Displacement compressors, Acceptance tests (scope)](https://www.evs.ee/en/iso-1217-2009)
- [EVS (Estonian Centre for Standardisation), ISO 8573-1:2010 Compressed air, Part 1: Contaminants and purity classes (scope)](https://www.evs.ee/en/iso-8573-1-2010)
- [SODECOTON, international open tender notice for two enclosed 37 kW screw air compressors with two dryers (2026), published by ARMP Cameroon](https://pridesoft.armp.cm/_lib/file/doc/0903/2026/03/26/SODECOTON/AVIS%20DAO%20N%C2%B0005-26%20fourniture%20d%E2%80%99un%20lot%20de%20deux%20(02)%20compresseurs%20d%E2%80%99air%20%C3%A0%20vis%20capot%C3%A9%20de%2037%20KW%20avec%20deux%20(02)%20s%C3%A9cheurs%20%C3%A0%20la%20SODECOTON.pdf)
- [Ayuntamiento de Zaragoza, drinking water plant: specification for a variable speed rotary screw air compressor (June 2014)](https://www.zaragoza.es/sede/servicio/contratacion-publica/anuncio/8708/document.pdf)
- [ULTRASCREW datasheet, p. 3](https://www.ultracontrolo.com/products/ultrascrew)

Reviewed: 2026-11-19. Ultra Controlo engineering. https://library.ultracontrolo.com/answers/what-should-a-compressor-tender-specify/