# ULTRAOX 560: 55.7 Nm³/h PSA oxygen plant

According to the 2026 ULTRAOX SC and ULTRAOX ST datasheets, the ULTRAOX 560 is listed at 55.7 Nm³/h of oxygen at 93% ± 3% purity, with an ULTRACON 14 generator and a maximum daily filling capacity of 178 cylinders (50 L at 150 bar).

In the model tables of the ULTRAOX SC and ULTRAOX ST datasheets, the 560 sits between the ULTRAOX 520 (52.4 Nm³/h) and the ULTRAOX 730 (73.0 Nm³/h). The two tables list the same oxygen flow, daily filling capacity and oxygen generator for the two versions.

## Datasheet values

| ULTRAOX 560 | Value in the 2026 datasheets |
|---|---|
| Oxygen flow | 55.7 Nm³/h |
| Max. daily filling capacity | 178 cylinders (50 L at 150 bar) |
| Oxygen purity | 93% ± 3% |
| Oxygen generator | ULTRACON 14 |
| Layout | Simplex |
| Versions | ULTRAOX SC and ULTRAOX ST, the same flow in both |

The ULTRAOX product page describes its size match as indicative, from the datasheet, with Ultra Controlo engineers confirming the configuration for the site.

## Compressor by altitude band

The ULTRAOX ST table lists an ULTRASCREW compressor for each altitude band: ULTRASCREW 75 at 0 to 1,000 m, ULTRASCREW 110 at 1,000 to 2,000 m and ULTRASCREW 110 at 2,000 to 3,000 m. The oxygen flow stays at 55.7 Nm³/h in all three bands.

The ULTRAOX SC table does not list the compressor of this model; its notes say that compressor data for the other models is available on request.

The ULTRAOX ST datasheet states that the power and pressure of the compressor can vary with the service conditions required for the facility. Ultra Controlo engineering confirms the configuration for each project.

## What the tables list with the ULTRAOX 560

The components tables of the two datasheets list the following for this model. The ULTRAOX SC table has no column for the ULTRAK tower or the ULTRASEP separator.

| Component | Listed for the ULTRAOX 560 |
|---|---|
| Aftercooler | ULTRACOOL 8 |
| Air treatment chain | CTA 40/1 |
| Refrigeration dryer | ULTRASEC 27 |
| Activated carbon tower (ULTRAOX ST) | ULTRAK 14 |
| Oil/water separator (ULTRAOX ST) | ULTRASEP 4 |
| Air receiver | 2 × 2,000 L, 11.5 bar |
| Oxygen generator | ULTRACON 14 |
| Oxygen process tank | 2,000 L, 11.5 bar |
| Oxygen storage tank | 2,000 L, 11.5 bar |

Tank pressures are maximum operating pressures.

For what each component does, see [what equipment comes with each ULTRAOX model](https://library.ultracontrolo.com/answers/what-equipment-comes-with-each-ultraox-model/).

## ULTRAOX SC or ULTRAOX ST

The 560 is listed in both versions. ULTRAOX SC uses oil-less ULTRACECO compressors and ULTRAOX ST uses ULTRASCREW screw compressors; see [ULTRAOX SC](https://library.ultracontrolo.com/products/ultraox-sc/) and [ULTRAOX ST](https://library.ultracontrolo.com/products/ultraox-st/), and the table of all 16 models in [ULTRAOX models compared](https://library.ultracontrolo.com/answers/ultraox-models-compared/).

### How many Nm³/h does the ULTRAOX 560 produce?

The 2026 ULTRAOX SC and ULTRAOX ST datasheets list 55.7 Nm³/h of oxygen at 93% ± 3% purity.

### Does the ULTRAOX 560 change with altitude?

The tables list 55.7 Nm³/h at 0 to 1,000 m, 1,000 to 2,000 m and 2,000 to 3,000 m. In the ULTRAOX ST the compressor is ULTRASCREW 75, then ULTRASCREW 110, then ULTRASCREW 110.

### How many oxygen generators does the ULTRAOX 560 use?

The tables list one ULTRACON 14 generator.

## Sources

- [ULTRAOX ST datasheet, 2026 edition (model and components tables, ULTRAOX 560)](https://www.ultracontrolo.com/products/ultraox-st)
- [ULTRAOX SC datasheet, 2026 edition (model and components tables, ULTRAOX 560)](https://www.ultracontrolo.com/products/ultraox)

Reviewed: 2026-11-18. Ultra Controlo engineering. https://library.ultracontrolo.com/products/ultraox-560/