Medical air
What filters does a medical air system need?
Which filters does a medical air system need, from the compressor to the pipeline?
Short answer
A medical air system typically has an inlet filter on each compressor, a water separator, a water filter and an oil filter, desiccant dryer columns, a dust filter, a carbon filter and a bacteria filter before the pipeline, as described in HTM 02-01 (2026).
Medical air is filtered in stages. HTM 02-01 (2026), the NHS England guidance for medical gas pipelines, describes this sequence for a typical medical air plant:
- Air-inlet filter immediately upstream of each compressor, a dry medium or grade CA paper element filter complying with BS ISO 5011.
- Inline cyclone water separator between each compressor and the receivers, with a timed solenoid drain.
- Water filter/separator and oil filter, fitted as individual components.
- Two desiccant dryer columns: one dries the air while the other is regenerated with dry air from the active column.
- Dust filter.
- Carbon filter.
- Bacteria filter, followed by the dew point sensor and test point of the dryer assembly.
The whole dryer assembly is duplicated by a second one to ensure continuity of supply. HTM 02-01 notes that a differential pressure gauge signals critical failure rather than servicing needs, so it does not replace regular inspection.
How Ultra Controlo builds it
The ULTRAMED treatment unit combines these stages: a high efficiency coalescing filter for water, oil, aerosols and particles above 0.01 µm; an activated carbon filter that reduces oil vapour and odours down to 0.003 mg/m³; two adsorption columns with desiccant for water vapour; a catalyst filter that converts carbon monoxide into carbon dioxide; and a final dust filter for particles carried over from the adsorption material. For medical air, Ultra Controlo advises adding a sterile air filter.
On ULTRAAR ME, each pressure regulator carries a sterile air filter with 99.999998% efficiency at 0.01 μm. ULTRAK activated carbon towers, which remove oil vapour by adsorption, need a coalescing filter upstream, and the datasheet recommends a 1 μm dust filter downstream.
More questions
Does medical air need a sterile filter?
HTM 02-01 includes a bacteria filter in the typical dryer system, and Ultra Controlo advises adding a sterile air filter to the ULTRAMED treatment unit for medical air.
Do oil-free compressors need fewer filters?
HTM 02-01 says oil-free compressors reduce filtration requirements and minimise the risk of oil contamination.
Sources
- NHS England, HTM 02-01 Medical gas pipeline systems (2026), Part A, 7.29, 7.34, 7.46 and 7.64 to 7.72
- ULTRAMED datasheet, p. 3
- ULTRAAR ME datasheet, p. 3
- ULTRAK datasheet, p. 2