Industry
Oil-injected screw compressor maintenance
What maintenance does an oil-injected rotary screw compressor need?
Short answer
According to Compressed Air Challenge Fact Sheet #5 (May 2026), a lubricant-injected rotary screw compressor needs its lubricant level inspected daily, its lubricant, lubricant filter and inlet filter maintained per the manufacturer, and its air/lubricant separator changed per the manufacturer or when pressure drop exceeds 10 psid, whichever is less.
Fact Sheet #5 says all equipment in a compressed air system should be maintained in accordance with manufacturers' specifications, and that manufacturers provide inspection, maintenance and service schedules that should be followed strictly. In many cases, it adds, it makes sense from efficiency and economic standpoints to maintain equipment more often than the intervals manufacturers recommend, which are primarily designed to protect equipment.
Basic maintenance checklist
| Item | What Fact Sheet #5 says |
|---|---|
| Inlet filter cartridges | Inspect and clean or replace per manufacturer specifications. Dirty filters increase energy consumption. |
| Compressor lubricant level | Inspect daily and top off or replace per manufacturer specifications. |
| Lubricant filter | Change per manufacturer specifications. |
| Air/lubricant separator | Change per manufacturer specifications or when pressure drop exceeds 10 psid, whichever is less. |
| Operating temperature | Verify that it is per manufacturer specification. |
| Air line filters | Replace particulate and lubricant removal elements when pressure drop exceeds 2 to 3 psid, and inspect all elements at least annually regardless of pressure drop indication. |
| Drain traps | Clean out debris and check operation periodically. |
The air/lubricant separator
The fact sheet says the air/lubricant separator in a lubricant-cooled rotary screw compressor generally starts with a 2 to 3 psid pressure drop at full load when new, and that maintenance manuals usually suggest changing it at about 10 psid. An earlier replacement may make sense in many cases, especially if electricity prices are high.
Fact Sheet #4 names lubricant separators among the most typical problem areas for pressure drop upstream of the compressor signal, and says this pressure rise can increase compressor drive energy by 1% of the connected power for each 2 psi of differential.
Lubricant and motor
In lubricant-injected rotary compressors the lubricant lubricates bearings, gears and intermeshing rotor surfaces, acts as a seal and removes most of the heat of compression. Only a lubricant meeting the manufacturer's specifications should be used. The fact sheet also says that the compressor lubricant and lubricant filter need to be changed per the manufacturer's specification, and that lubricant can become corrosive and degrade both the equipment and system efficiency.
Motors should be lubricated per the manufacturer's specification, which can be anywhere from every 2 months to every 18 months depending on annual hours of operation and motor speed.
Benchmark the compressor
One way to tell whether a system is maintained well is to benchmark it by tracking power, pressure and flow. If power use at a given pressure and flow goes up, the efficiency of the system is degrading. On new systems the specifications should be recorded when the system is first set up and operating properly.
ULTRASCREW
The ULTRASCREW datasheet describes an oil injected rotary screw compressor. On ultracontrolo.com the fixed speed version (FSD) is presented with a compact footprint with easy servicing, and the variable speed version (VSD) with air/oil cooling with cyclonic separator and a pressure relief valve. The ULTRASCREW datasheet and product page used for this answer give no service intervals, so intervals come from the manufacturer's specification for the unit, as Fact Sheet #5 says. For the compressors of a hospital plant, see what maintenance a medical air plant needs and the ULTRASCREW range.
More questions
How often should the lubricant level of a screw compressor be checked?
Fact Sheet #5 says to inspect the compressor lubricant level daily and to top off or replace it per manufacturer specifications.
When should an air/lubricant separator be changed?
Per manufacturer specifications or when pressure drop exceeds 10 psid, whichever is less, according to Fact Sheet #5; a new separator generally starts at a 2 to 3 psid pressure drop at full load.
Sources
- Compressed Air Challenge, Compressed Air Systems Fact Sheet #5: Maintenance of Compressed Air Systems for Peak Performance (May 2026, Rev. 1)
- Compressed Air Challenge, Compressed Air Systems Fact Sheet #4: Pressure Drop and Controlling System Pressure (May 2026, Rev. 1)
- ULTRASCREW datasheet, p. 2
- ULTRASCREW product page, ultracontrolo.com (checked 18 November 2026)
Ultra Controlo figures come from its technical datasheets. Third-party facts were read at the source on the date shown.