Pressure-reducing station (PRS)

Under HTM 02-01 (2026), the NHS England guidance, a pressure-reducing station (PRS) is the station that should be provided where the pressure needs to be reduced on an air system, for example from surgical air to medical air.

Request a quote

HTM 02-01 (2026) says the PRS should be a duplex system, so that the flow of gas is not interrupted in the event of maintenance or component failure. It should be set up with a lead and lag regulator with a maximum of 50 kPa differential to maintain line pressure.

According to the HTM, each side of the PRS should comprise a pressure regulator, an analogue pressure gauge, a safety relief valve, a terminal unit for testing, a non-return valve and a pressure transducer between two line valves. An alarm should be installed to monitor the PRS. For context, the HTM says a pressure of 400 kPa is required for medical air to drive ventilators and for other respiratory applications.

In Ultra Controlo plants

The ULTRAAR ME datasheet (2026) lists a pressure reduction and sterile filtration system fitted twice in the plant, with duplex pressure reducers each adjustable from 3 to 10 bar, non return reducers, an integrated pressure gauge and isolation valves for section switchover. This is a description of the datasheet; it is not compared here with the HTM paragraphs.