Turndown

Turndown is how far below its full capacity a piece of equipment can keep operating; a 2010 US EPA report on wastewater treatment explains a 5:1 turndown ratio as a system capable of operating at one fifth of its full capacity.

The same EPA report gives nominal turndown for each type of blower as a percentage of rated flow and notes, for multi-stage centrifugal blowers, that efficiency decreases with turndown. The US Department of Energy's compressed air sourcebook (2016) uses the word for instruments too, listing turndown range, with repeatability, under the accuracy of a flow meter.

For PSA oxygen plants, WHO's Foundations of medical oxygen systems (2023) says they are typically manufactured to operate non-stop; the ways guidance describes running a plant below its rated output are in can a PSA plant run at part load. ULTRAOX plants start and stop oxygen production automatically in response to demand from the distribution system (ULTRAOX datasheet 2022, p. 6), and the ULTRAOX SC is modular and switches compressors and starts its generators in cascade (ULTRAOX SC datasheet, p. 2).

Sources

Ultra Controlo figures come from its technical datasheets. Third-party facts were read at the source on the date shown.