Medical gas library

Medical air

Gardner Denver ESM and VS oil-lubricated screw compressors

On its EMEIA website, Gardner Denver lists oil-lubricated rotary screw compressors, with ESM models at fixed speed and VS models at variable speed, including the two-stage FourCore ESM/VS 110FC to 290FC, which its brochure gives as 110 to 250 kW.

Fixed speed (ESM) or variable speed (VS)

Gardner Denver says variable speed compressors are generally applied when air demand varies significantly throughout a shift, because they use less power per unit of air than fixed speed machines at part load. It also cautions that VS compressors are many times recommended when they are not needed or do not project a reasonable return, and that dividing the air requirement between two or more compressors, often combining fixed and variable speed units, is frequently the most efficient design and keeps some air available if one unit goes down. See VSD or fixed speed.

The manufacturer describes rotary screw compressors as designed for continuous compressed air use with a consistent flow, unlike reciprocating compressors, and says the ESM(e)/VS 30 to 132 series is designed for continuous 24-hour use in critical industrial processes.

The ESM and VS ranges

Summary values from the Gardner Denver brochures linked from its EMEIA site. The FourCore brochure states free air delivery to ISO 1217, Edition 4, Annex C and Annex E, at 1 bar a intake pressure and 20 °C intake temperature.
RangeMotor powerPressureFree air deliverySource
ESM/VS 30 to 4530 to 45 kW5 to 13 bar1.33 to 8.90 m³/minESM30 to 45e brochure
ESM/VS 55 to 7555 to 75 kW5 to 13 bar2.1 to 14.9 m³/minESM55 to 75 brochure
ESM/VS 90 to 13290 to 132 kW5 to 13 bar5.3 to 24.8 m³/minESM90 to 132 brochure
ESM/VS 110FC to 290FC (FourCore, two-stage)110 to 250 kW5 to 10 bar9.16 to 47.9 m³/minFourCore brochure G8 27.EN.10/23.CI

The ESM55 to 75 brochure also offers an integrated refrigeration dryer designed to work one to one with the compressor.

Design points the manufacturer lists

  • Two-stage compression: stage one compresses atmospheric air part way, stage two takes it to the discharge pressure; Gardner Denver says this improves efficiency but adds cost and complexity. In FourCore, one motor drives four rotors in a single semi-integrated casting.
  • On the ESM(e)/VS 30 to 132 series, a semi-integrated airend with integrated oil filter and oil regulation valve, with fewer external components and pipework.
  • Separator filtration with an oil carryover below 3 ppm according to the 30 to 45 kW and 90 to 132 kW brochures; the 90 to 132 kW and FourCore brochures describe two-stage filtration.
  • AEON 9000 SP synthetic lubricant as standard on the ESM(e)/VS 30 to 132 series, and iConn real-time monitoring as standard on the FourCore ESM/VS 110FC to 290FC, according to its FourCore brochure.
  • Heat recovery systems on the 30 to 132 kW series, factory fitted or as retrofit kits; the 30 to 45 kW brochure states that the VS power drive system exceeds the class IES2 EN61800-9 requirements.
  • Airends designed and made in-house; the EMEIA page shows airend manufacturing in Simmern, Germany.

Lubricated or oil-free air

On its EMEIA compressors page, Gardner Denver says industries such as pharmaceuticals, food and beverage and electronics typically require oil-free air to meet strict contamination control protocols, and that rotary screw compressors are often the choice for continuous-use applications. For those sectors, see Gardner Denver oil-free screw compressors.

In Portugal, the Ultra Controlo Industrial 2026 catalogue (p. 12) lists Gardner Denver lubricated screw compressors for continuous operation among its partner-brand equipment, and UltraCare covers maintenance and original spare parts for partner brands (p. 22).

More questions

What do ESM and VS mean on a Gardner Denver compressor?

On the Gardner Denver EMEIA site, ESM models are fixed speed and VS models are variable speed lubricated screw compressors.

How much oil reaches the air from a Gardner Denver lubricated screw compressor?

The ESM/VS 30 to 45 kW and 90 to 132 kW brochures give an oil carryover below 3 ppm from the separator filtration.

Sources

Ultra Controlo figures come from its technical datasheets. Third-party facts were read at the source on the date shown.

Reviewed: · Ultra Controlo engineering · Markdown version