How does a rotary vane vacuum pump work?

Short answer

Thomas describes a rotary vane pump as a positive-displacement device with a rotor mounted eccentrically in a housing: sliding vanes move in and out of their slots to form chambers that expand to draw gas in and contract to compress and discharge it, which Elmo Rietschle describes as pressure increase through volume reduction.

The cycle

The Thomas technology page adds that the rotor sits near the top of the cylindrical housing and that, when it starts turning, centrifugal force throws the blades out so that they slide against the inner surface of the cylinder. Some models have exhaust valves that stop the discharged air flowing back once the maximum pressure is reached. The US EPA WaterSense at Work guide (October 2012) counts vane pumps among the dry, positive displacement types that do not use water to make the vacuum seal.

Oil-lubricated pumps

In an oil-lubricated pump, Elmo Rietschle says, the oil is lubricant, sealing agent and cooling medium. These pumps, also known as oil-flooded or oil-sealed, use the oil seal to reach deeper vacuum levels, and the oil carries away the heat of compression. A de-oiling chamber filters the oil-gas mixture and separates oil particles from the gas. Its V-VCS reaches an ultimate vacuum of 0.5 mbar (abs.), and the V-VCS and V-VCX datasheet (D236) lists an oil/air heat exchanger, a fine mesh filter and a gas ballast valve.

Dry-running pumps

Dry-running pumps operate without oil lubrication. Thomas says oil-less designs use self-lubricating vanes and need no routine oil changes; its PICOLINO VTE pumps have four graphite vanes with a low but permanent wear rate, which increases if the inlet air is contaminated. Elmo Rietschle cools its dry-running pumps through optimised cooling air pathways and vents, thermally separates the suction and compression chambers, and fits the V-VTN with a micro-fine filter on the suction side; the V-VTN reaches an ultimate vacuum of 150 mbar (abs.).

Wet gas

For gas with high moisture, the Elmo Rietschle V-VCX has chemically resistant resin vanes and an extensive, adjustable gas ballast valve. Its datasheet describes glass-fibre reinforced epoxy resin slide blades and says the functional parts are more resistant to water steam and solvents. See dry-running or oil-lubricated vane pumps.

Ultra Controlo distributes and services Elmo Rietschle and Thomas in Portugal as partner brands, and its UltraCare programme covers preventive and corrective maintenance, original spare parts and emergency support for partner-brand equipment.

More questions

Why do the vanes stay against the housing wall?

Thomas says that when the rotor starts turning, centrifugal force throws the blades out of their slots so that they slide against the inner surface of the cylinder.

When should dry-running vanes be checked?

For the PICOLINO VTE pumping clean air, Thomas says the vanes should be checked at the latest after 4000 running hours and thereafter every 1000 hours, with shorter intervals for other conditions.

Sources

Ultra Controlo figures come from its technical datasheets. Third-party facts were read at the source on the date shown.