Industry
How is an industrial air compressor sized?
How is an industrial air compressor sized for a factory?
Short answer
Compressed Air Challenge Fact Sheet #1 (May 2026) says a compressed air system is sized from the air quality, quantity and pressure the end uses need, with capacity found by summing the average air consumption of each tool and process, not their maximum requirements.
Fact Sheet #1 of the Compressed Air Challenge (May 2026, Rev. 1) defines compressed air needs as the air quality, quantity and level of pressure required by the end uses in a plant, and says that assessing them carefully ensures a compressed air system is configured properly. The three needs are taken in turn below.
Air quality
The fact sheet lists four levels of compressed air quality, from plant air to breathing air. Industrial applications typically use one of the first three, and quality is determined by the dryness and contaminant level the end uses require, which is achieved with filtering and drying equipment.
| Quality | Applications listed in Fact Sheet #1 |
|---|---|
| Plant air | Air tools, general plant air |
| Instrument air | Laboratories, paint spraying, powder coating, climate control |
| Process air | Food and pharmaceutical process air, electronics |
| Breathing air | Hospital air systems, diving tank refill stations, respirators for cleaning and/or grit blasting |
The fact sheet adds that the higher the quality, the more the air costs to produce. Whether the air must be lubricant-free is one of the main factors: see oil-injected or oil-free screw compressors for industry.
Air quantity
Required capacity can be found by summing the requirements of the tools and process operations at the site, taking load factors into account. The total air requirement is not the sum of the maximum requirements for each tool and process, but the sum of the average air consumption of each. High short-term demands should be met by air stored in an air receiver, and a system may have more than one receiver.
A thorough evaluation of demand may result in a control strategy that meets it with reduced overall compressor capacity. Oversized air compressors are extremely inefficient, because most systems use more energy per unit volume of air produced when operating at part load, and in many cases it makes sense to use multiple, smaller compressors with sequencing controls.
Load profile
The variation of air demand over time is the load profile, and it is a major consideration in system design. Plants with wide variations in demand need a system that operates efficiently at part load, where multiple compressors with sequencing controls may be more economical; plants with a flatter load profile can use simpler control strategies. Fact Sheet #6 says few air systems operate at full load all the time, so part-load performance is critical and is primarily influenced by compressor type and control strategy. See how several compressors are controlled together and fixed speed or variable speed.
Pressure
Different tools and process operations need different pressures, and the required pressure levels must take into account system losses from dryers, separators, filters and piping. As a rule of thumb, every 2 psi increase in operating pressure requires an additional 1% in operating energy costs. Supplying a higher pressure than necessary also creates artificial demand, the excess volume of air used by unregulated end uses.
Fact Sheet #4 says a properly designed system should have a pressure loss of much less than 5% of the compressor discharge pressure, measured from the receiver tank output to the point of use. See why pressure drop costs energy and how working pressure changes screw compressor output.
Reading a compressor datasheet
Once quality, quantity and pressure are known, a compressor is chosen from the capacity its datasheet states at that pressure. The ULTRAAR ME datasheet (2026) lists the fixed speed ULTRASCREW compressors per unit: from ULTRASCREW 4 FSD, 4 kW and 22 Nm³/h at 10 bar, to ULTRASCREW 132 FSD, 132 kW and 1,170 Nm³/h at 10 bar. The ULTRASCREW page on ultracontrolo.com also lists capacities at 13 bar, from 38 to 840 Nm³/h.
In the ULTRAAR ME and ULTRAOX ST plants, the compressor is sized by altitude band, up to 3,000 m. Compare capacities only at the same pressure and on the same basis: see how air compressor efficiency is compared and free air delivery.
More questions
Is the compressor capacity the sum of the maximum demand of each tool?
No. Fact Sheet #1 says the total air requirement is the sum of the average air consumption of each tool and process, and that high short-term demands should be met by air stored in an air receiver.
Why not choose a much larger compressor to be safe?
Fact Sheet #1 says oversized air compressors are extremely inefficient, because most systems use more energy per unit volume of air produced at part load, and that multiple, smaller compressors with sequencing controls often make sense.
Sources
- Compressed Air Challenge, Compressed Air Systems Fact Sheet #1: Assessing Compressed Air Needs (May 2026, Rev. 1)
- Compressed Air Challenge, Compressed Air Systems Fact Sheet #4: Pressure Drop and Controlling System Pressure (May 2026, Rev. 1)
- Compressed Air Challenge, Compressed Air Systems Fact Sheet #6: Compressed Air System Controls (May 2026, Rev. 1)
- ULTRAAR ME datasheet (2026), configuration table
- ULTRASCREW product page, ultracontrolo.com (checked 18 November 2026)
Ultra Controlo figures come from its technical datasheets. Third-party facts were read at the source on the date shown.