Medical gas library

Medical air

How much does a compressed air leak cost per year?

Short answer

Under the US DOE leak cost formula (Compressed Air Tip Sheet #3, 2004), a leak costs its flow rate times the compressor power needed per unit of flow, the annual operating hours and the electricity price per kWh; the flow rises with system pressure and with the square of the hole diameter.

The formula

The US Department of Energy tip sheet Minimize Compressed Air Leaks (Tip Sheet #3, revised August 2004) prices leaks as: number of leaks × leakage rate (cfm) × kW per cfm × annual operating hours × electricity price per kWh. Its worked example assumes a compressed air generation requirement of approximately 18 kW per 100 cfm. How to establish a plant's own power per unit of flow is covered in the cost of compressed air per cubic metre.

Leak flow by hole size

The same tip sheet tabulates leakage rates for approximately equivalent orifice sizes. Leakage rates are a function of the supply pressure in an uncontrolled system and increase with higher system pressures, and they are proportional to the square of the orifice diameter. An extract:

Leakage rates in cfm, US DOE Compressed Air Tip Sheet #3 (August 2004). The tip sheet says the values should be multiplied by 0.97 for well-rounded orifices and by 0.61 for sharp ones.
Pressure (psig)1/16 in1/8 in1/4 in
704.6618.6274.4
1006.3125.22100.9
1257.6630.65122.2

What the 2026 fact sheet adds

Compressed Air Systems Fact Sheet #7 (Compressed Air Challenge, May 2026, Rev. 1) says leaks sometimes waste 20 to 30% of a compressor's output, that a typical plant that has not been well maintained will likely have a leak rate equal to 20% of total production capacity, and that proactive leak detection and repair can reduce leaks to less than 10% of compressor output. Its Cost of Leaks box gives an annual cost for leaks of 1/16, 1/8 and 1/4 inch, calculated with a stated electricity rate, constant operation and an efficient compressor. Beyond energy, leaks drop system pressure, force equipment to cycle more often and shorten the life of almost all system equipment, add maintenance and unscheduled downtime, and can lead to adding unnecessary compressor capacity.

Measuring a plant's own leak load

For compressors with start/stop controls, Fact Sheet #7 starts the compressor when there are no demands on the system, with all air-operated end-use equipment turned off, and times the load and unload cycles: leakage (%) = (T × 100) / (T + t), with T the on-load and t the off-load time in minutes. With other controls it uses the total system volume V in cubic feet and the time T in minutes for the pressure to fall from the normal operating pressure P1 to a lower pressure P2 of about one-half of it: leakage (cfm free air) = (V × (P1 − P2) / T × 14.7) × 1.25, with P1 and P2 in psig; the 1.25 multiplier corrects leakage to normal system pressure.

Because leak flow depends on pressure, Fact Sheet #7 notes that reduced system pressure will result in reduced leakage rates, and the DOE tip sheet advises prioritising leaks as they are identified and fixing the largest ones first. Finding and repairing leaks is covered in compressed air leaks.

Once leaks have been repaired, Fact Sheet #7 says the compressor control system should be re-evaluated to realise the total savings potential. Ultra Controlo supplies ULTRASCREW oil injected rotary screw compressors; the ULTRASCREW datasheet describes a variable speed version that can operate over 5 to 14 bar.

More questions

Does a leak cost more at higher pressure?

Yes. The DOE tip sheet (2004) says leakage rates increase with higher system pressures, and Fact Sheet #7 (May 2026) says reduced system pressure will result in reduced leakage rates.

Which leaks should be fixed first?

The DOE tip sheet (2004) says that as leaks are identified it is important to prioritise them and fix the largest ones first.

Sources

Ultra Controlo figures come from its technical datasheets. Third-party facts were read at the source on the date shown.

Reviewed: · Ultra Controlo engineering · Markdown version