Medical gas library

Industry

How to work out the cost of compressed air per cubic metre

How do you work out what one cubic metre of compressed air costs?

Short answer

Compressed Air Challenge Fact Sheet #9 (May 2026) works out a compressor's annual electricity cost from its full-load power, motor efficiency, operating hours, load pattern and electricity price; the 2016 DOE sourcebook combines measured power with measured flow to get specific power, the power used for a given flow of air.

Step 1: the compressor's energy bill

Fact Sheet #9 (May 2026, Rev. 1) calls electricity by far the largest expense of owning and operating a compressed air system. For a quick estimate at full load it needs the motor full-load brake horsepower, the motor efficiency, the annual hours of operation and the cost of electricity per kWh:

  • Annual electricity cost = full-load bhp × 0.746 kW/hp × (1/0.9) × annual hours × electricity cost per kWh. The 0.9 assumes a 90% efficient motor, reasonable for a modern system larger than 50 hp; for an older rewound or a smaller motor, 80% (or the nameplate efficiency) should be used.
  • Motors are commonly loaded into their service factor: a 100 hp nameplate motor may be loaded to 110 bhp at full capacity and pressure, and the higher figure should then be used.
  • A more accurate route uses measured full-load amps and volts with the power factor: (amps × volts × 1.732 × power factor) / 1,000 × annual hours × electricity cost per kWh.
  • For part-load operation, the calculation is repeated for the share of time running fully loaded and the share running unloaded, with a factor for the reduced load on the motor in the unloaded share, and the two results are added.

The fact sheet stresses that these calculations give a good estimate of energy consumption, not an exact number.

Step 2: the air actually delivered

The 2016 DOE sourcebook (Fact Sheet 10, baselining) measures flow on the main compressor room output during all shifts. Flow, in conjunction with power or energy input, gives the system specific power, the amount of power consumed for a given flow output, which the sourcebook tracks as cfm per kW or kW per 100 cfm at a given pressure. Mass flow readings are based on standard reference conditions, which should be checked for the instrument used. Fact Sheet #8 (2026) gives standard conditions for compressor ratings of 1 bar, 20°C and dry air, and names ISO 1217 as the recognized performance standard for displacement compressors (free air delivery, normal cubic metre).

Step 3: from energy to cost per unit of air

The DOE leak tip sheet (Tip Sheet #3, August 2004) prices leaked air as number of leaks × leakage rate (cfm) × kW per cfm × hours × electricity price per kWh, and its example assumes approximately 18 kW per 100 cfm. In that formula, the cost of the leaked air depends on the power needed per unit of flow, the hours and the price of a kWh. The sourcebook also recommends relating energy to production, as kW × hours per unit of production.

What else belongs in the number

Fact Sheet #9 adds that electricity bills usually combine energy and demand charges with seasonal or tiered rates, so the actual marginal cost of electricity needs to be considered; that annual maintenance costs can be 10% or more of the initial cost of the system; and that, for a system operating around 100 psig, every 2 psi of operating pressure requires an additional 1% in operating energy costs.

The ULTRASCREW datasheet states that its air flow is measured in accordance with ISO 1217:2009, Annex C, with values at 1 bar absolute, 0% relative humidity and 20 °C inlet air temperature.

More questions

Should the motor nameplate power be used?

Only if the motor is not loaded into its service factor: Fact Sheet #9 (May 2026) says a 100 hp nameplate motor may be loaded to 110 bhp at full capacity, and the higher figure should then be used.

Is the price per kWh enough?

No. Fact Sheet #9 (May 2026) says bills usually include demand charges and seasonal or tiered rates, so the actual marginal cost of electricity needs to be considered.

Sources