What is pressure dew point in compressed air?

What is pressure dew point in compressed air, and why does it matter?

Short answer

The US Department of Energy compressed air sourcebook (third edition, 2016) defines pressure dew point as the temperature at which, for a given pressure, water will begin to condense out of air; it links condensation in the distribution piping to corrosion and contamination of point-of-use processes.

Pressure dew point and atmospheric dew point

The sourcebook defines dew point as the temperature at which moisture in the air will begin to condense if the air is cooled at constant pressure. When air is compressed and occupies a smaller volume, it can no longer contain all of the moisture possible at atmospheric conditions, and some of it drops out as liquid condensate; the result is a difference between the dew point at atmospheric conditions and the dew point at higher pressures.

Portugal's ACSS specification for hospital technical compressed air, ET 08/2010 (V.2025), shows the size of the difference: it states ISO 8573-1 humidity class 4 as a pressure dew point of +3 °C or lower at 20 °C mean temperature and 0.7 MPa, equivalent to an atmospheric dew point of −21 °C or lower.

Why it matters

Air leaving an aftercooler and moisture separator is typically saturated, the DOE sourcebook says, and any further radiant cooling in distribution piping exposed to colder temperatures causes further condensation, with corrosion and contamination of point-of-use processes; it adds that the problem can be avoided by the proper use of compressed air dryers. Drying has its own cost: the sourcebook says drying beyond the required pressure dew point results in unnecessary energy and costs, and the Compressed Air Challenge Fact Sheet #11 (May 2026) says drying should only be performed to the degree needed for the proper functioning of the equipment and the end use.

The same fact sheet gives the usual levels: refrigerant-type dryers, the most common, provide a pressure dew point of 35 to 39 °F, acceptable for many applications, and twin tower desiccant-type dryers, the most effective at removing moisture, are typically rated at −40 °F.

How it is measured

The ISO 8573 series for compressed air has separate parts for measuring humidity and liquid water; see ISO 8573-3: how humidity in compressed air is measured and ISO 8573-9: how liquid water in compressed air is measured.

The ULTRADRY datasheet states that the ULTRADRY adsorption dryer gives a pressure dew point range of -40 °C to -70 °C (see ULTRADRY).

More questions

Is a lower pressure dew point always better?

No: the DOE sourcebook (2016) says drying beyond the required pressure dew point results in unnecessary energy and costs, and CAC Fact Sheet #11 (May 2026) says to dry only to the degree the equipment and end use need.

How different are pressure and atmospheric dew point?

Portugal's ACSS ET 08/2010 (V.2025) equates a pressure dew point of +3 °C or lower at 0.7 MPa and 20 °C with an atmospheric dew point of −21 °C or lower.

Sources

Ultra Controlo figures come from its technical datasheets. Third-party facts were read at the source on the date shown.