Medical gas library

Medical air

Coalescing filter vs activated carbon filter in compressed air

Short answer

Compressed Air Challenge Fact Sheet #11 (May 2026) says coalescing filters remove lubricant and moisture, while adsorbent filters handle vaporous contaminants; it recommends a coalescing-type filter before a desiccant-type dryer to prevent fouling of the desiccant bed.

The two filters do different jobs, and compressed air treatment chains normally place them in sequence. The table sets out what two published sources say each one removes.

FilterWhat it removesSource
Coalescing filterLubricant and moisture; solid particles and water and oil aerosolsCompressed Air Challenge Fact Sheet #11 (May 2026); ACSS ET 08/2010 (Portugal)
Activated carbon (adsorbent) filterVaporous contaminants; hydrocarbon (oil) vapours and odours, by adsorptionCompressed Air Challenge Fact Sheet #11 (May 2026); ACSS ET 08/2010 (Portugal)

Why both are used

Fact Sheet #11 recommends a coalescing-type filter before a desiccant-type dryer to prevent fouling of the desiccant bed, and a particulate filter after it to remove desiccant fines. It also says that filtration only to the level required by each application will minimise pressure drop and energy consumption.

In Portugal, the ACSS specification ET 08/2010 (V.2025) for technical compressed air in hospitals describes a chain downstream of the wet receiver: a coalescing filter immediately before each dryer, typically filtering particles down to 1 µm; a high-efficiency coalescing filter after the dryer and dry receiver; and an activated carbon filter. It adds that an activated carbon filter at the end of the line is always an option that should be considered. This is a national hospital specification for non-medical air, not a general rule.

In Ultra Controlo datasheets

The ULTRAMED datasheet lists a high efficiency coalescing filter as the first stage, for water, oil and aerosols removal and particulate above 0.01 µ, followed by a high efficiency activated carbon filter that reduces oil vapour and odours down to 0.003 mg/m³. The air quality table of the same datasheet lists oil separately, below 0.01 mg/m³.

The ULTRAK datasheet describes activated carbon towers that separate oil vapours from compressed air by adsorption. It states that a coalescing filter is required upstream and recommends a 1 µm dust filter downstream. It lists a nominal residual oil vapour content below 0.003 mg/m³, a quality class for oils of 0/1 under ISO 8573-1, and a pressure drop of 20 mbar when new and dry.

More questions

Can a coalescing filter remove oil vapour?

Fact Sheet #11 lists coalescing filters for lubricant and moisture and adsorbent filters for vaporous contaminants; ACSS ET 08/2010 assigns hydrocarbon vapour removal by adsorption to the activated carbon filter.

Which filter goes first?

The ULTRAK datasheet requires a coalescing filter upstream of its carbon towers, and Fact Sheet #11 recommends a coalescing-type filter before a desiccant-type dryer.

Sources

Ultra Controlo figures come from its technical datasheets. Third-party facts were read at the source on the date shown.

Reviewed: · Ultra Controlo engineering · Markdown version