Medical gas library

Medical air

How is a compressed air dryer sized?

How is a compressed air dryer sized for air flow, working pressure and inlet temperature?

Short answer

The 2016 US DOE compressed air sourcebook says dryers must be sized by taking into account worst case operating inlet temperature, system pressure and ambient temperature, because dryer ratings are based on standard inlet conditions and a higher inlet temperature or lower inlet pressure reduces rated capacity.

A dryer's catalogue capacity is stated at reference conditions. The 2016 US DOE sourcebook says dryer ratings usually are based on standard dryer inlet conditions, 100 psig, 100 °F inlet compressed air temperature and 100 °F ambient temperature, and that deviations from these conditions affect the capacity of a dryer. An increase in inlet temperature or a decrease in inlet pressure reduces the rated capacity, and most manufacturers provide correction factors for this.

What the sources say to size for

  • Worst case, not average. The sourcebook says dryers must be sized by taking into account worst case operating inlet temperature, system pressure and ambient temperature.
  • The dew point the use needs. The sourcebook says dryer selection for the rated conditions should be based on the required pressure dew point and the estimated cost of operation, and that where a pressure dew point of less than 35 °F is required, a refrigerant-type dryer cannot be used. It adds that drying beyond the required pressure dew point results in unnecessary energy and costs.
  • Pressure drop. The sourcebook says the pressure drop through a compressed air dryer is typically 3 to 5 psi and should be taken into account in system requirements. Compressed Air Challenge Fact Sheet #11 (May 2026) says the complete drying, filtration and distribution system should be sized and arranged so that the total pressure drop from the compressor to the points of use is much less than 10% of the compressor discharge pressure.
  • Part load. Where average loading conditions are less than the dryer rating, the sourcebook says units with good part load efficiency through efficient control can save energy.
  • Design conditions. Fact Sheet #11 says air treatment equipment should be operated as close to the manufacturer's design conditions as possible.

How two Ultra Controlo dryer datasheets state their conditions

ULTRADRY (adsorption)ULTRASEC (refrigeration)
Flow in the datasheet tableTable values are at a compressed air inlet temperature of +35 °C and 7 bar g operating pressure, with a pressure dew point of −40 °CThe table lists flow rate in m³/h, l/min and scfm for models USL 1 to USL 39, from 21 to 17,664 m³/h; it does not state the reference conditions for these flow rates
Inlet air temperatureMinimum +5 °C, maximum +50 °CMaximum 70 °C for ULTRASEC standard, 100 °C for ULTRASEC-HT
Operating pressureMinimum 4 bar g, maximum 16 bar gThe datasheet gives no operating pressure range

The ULTRASEC datasheet also estimates that an increase of 1 bar on the compressor costs about 7% of the installed motor power, and says the lower pressure drop caused by dryers and filters lowers energy consumption.

ISO 7183:2007, the standard for compressed-air dryer specifications and testing, specifies the performance data that are necessary to state and the test methods for different types of dryers, according to its iso.org abstract. See ISO 7183.

More questions

Does a dryer keep its rated flow when the inlet air is hotter?

No. The 2016 US DOE sourcebook says an increase in inlet temperature or a decrease in inlet pressure reduces the dryer's rated capacity, and that most manufacturers provide correction factors.

Can a refrigerant-type dryer be used if a very low pressure dew point is needed?

The 2016 US DOE sourcebook says that where a pressure dew point of less than 35 °F is required, a refrigerant-type dryer cannot be used.

At what conditions are the ULTRADRY datasheet table values given?

The ULTRADRY datasheet gives them at a compressed air inlet temperature of +35 °C and 7 bar g operating pressure, with a pressure dew point of −40 °C.

Sources

Ultra Controlo figures come from its technical datasheets. Third-party facts were read at the source on the date shown.

Reviewed: · Ultra Controlo engineering · Markdown version