Medical gas library

Industry

How is an industrial air receiver sized?

How is the volume of an industrial compressed air receiver calculated?

Short answer

The US Department of Energy compressed air sourcebook (third edition, 2016) gives the receiver volume as the time allowed for the pressure drop, times the air demand in cfm of free air, times atmospheric pressure, divided by the difference between the initial and final receiver pressure.

Fact Sheet #11 of the Compressed Air Challenge (May 2026, Rev. 01) says air receivers are designed to provide a supply buffer to meet short-term demand spikes which can exceed the compressor capacity. They also dampen compressor pulsations, separate out particles and liquids, and make the compressed air system easier to control. Installing a larger receiver to meet occasional peak demands can even allow the use of a smaller compressor.

The sizing formula

The DOE sourcebook (third edition, 2016) gives the receiver volume V as T x C x Pa, divided by (P1 - P2), where:

  • V is the receiver volume, in cubic feet;
  • T is the time allowed, in minutes, for the pressure drop to occur;
  • C is the air demand, in cubic feet per minute (cfm) of free air;
  • Pa is the absolute atmospheric pressure, in psia;
  • P1 is the initial receiver pressure and P2 the final receiver pressure, both in psig.

The formula assumes the receiver is at ambient temperature and that no air is being supplied to it by the compressors. If a compressor runs while air is drawn from the receiver, the sourcebook says C is replaced by C - S, where S is the surplus compressor capacity, in cfm of free air.

The sourcebook adds that in the past, mainly with reciprocating compressors, the rule of thumb for a primary air receiver was 1 to 3 gallons per cfm of compressor capacity. It says this is no longer regarded as good practice, and that the recommended primary receiver size will vary with the type of compressor and capacity control used. See how an industrial air compressor is sized for the demand side.

Where the receiver goes

The sourcebook says there are two views on the position of the primary receiver. Before the dryer, it may provide additional radiant cooling and drop out some condensate and entrained oil, but it is then filled with saturated air. After the dryer, a sudden demand is met with dried air. One way to resolve this is to install storage both upstream and downstream of the dryer, with the downstream storage equal to or larger than the upstream storage. Fact Sheet #11 says a best practice is to use multiple receivers, a wet receiver before the dryer and a dry receiver directly after it, and that receivers close to points of intermittent use reduce pressure swings. See should the dryer go before or after the air receiver.

What storage does for the compressors

  • For load/unload compressors, the sourcebook says adequate storage acts to effectively increase efficiency.
  • Storage can help systems ride through a compressor failure or short energy outages (Fact Sheet #11).
  • For an application with high intermittent demand, one strategy in the sourcebook is correctly sizing and locating a secondary air receiver close to the point of that demand.
  • Variable speed compressors need proper effective storage: see the speed range of a variable speed screw compressor.

For the receiver of a hospital medical air plant, which has its own guidance, see air receiver.

More questions

What does an air receiver do?

Fact Sheet #11 says it provides a supply buffer for short-term demand spikes, dampens compressor pulsations, separates out particles and liquids and makes the system easier to control.

What if the compressor keeps running while air is drawn?

The sourcebook says the formula is then modified so that C is replaced by C - S, where S is the surplus compressor capacity in cfm of free air.

Sources

Ultra Controlo figures come from its technical datasheets. Third-party facts were read at the source on the date shown.

Reviewed: · Ultra Controlo engineering · Markdown version