Medical gas library

Service and projects

What causes oil carryover from an oil-injected screw compressor?

Short answer

In its 2016 sourcebook, the US Department of Energy said lubricant carryover into delivered air from a lubricant-injected rotary screw compressor requires proper maintenance of the air/lubricant separator and of the lubricant itself, and that the separator vessel is relieved gradually on unloading to prevent the lubricant foaming.

In a lubricant-injected screw compressor, the lubricant is part of the compression process: the Compressed Air Challenge (CAC) Fact Sheet #5 (May 2026) says it lubricates bearings, gears and intermeshing rotor surfaces, acts as a seal and removes most of the heat of compression. The same fact sheet lists the air lubricant separator, the lubricant and the lubricant filter among the main maintenance areas of the package.

Separator and lubricant

  • Separator: CAC Fact Sheet #5 says to change the air lubricant separator per manufacturer specifications or when its pressure drop exceeds a set limit, whichever comes first.
  • Lubricant condition: inspect the level daily, top off or replace, and change the lubricant filter, all per manufacturer specifications; lubricant can become corrosive and degrade the equipment (CAC Fact Sheet #5). The 2016 DOE sourcebook recommended lubricant sampling and analysis.
  • Lubricant type: only a lubricant meeting the manufacturer's specifications should be used (CAC Fact Sheet #5).
  • Unloading: the 2016 sourcebook explained that when the compressor unloads, the lubricant sump/separator vessel pressure is relieved gradually to prevent foaming of the lubricant, with the potential of excessive lubricant carryover.

What one manufacturer states

Gardner Denver gives an oil carryover of less than 3 ppm for the amply dimensioned filtration of its ESM 30 to 45e lubricated screw range and for the two-stage filtration of its ESM 90 to 132 range. By contrast, it says oil-free compressors have no oil present in the compression chamber, eliminating the risk of oil contaminating the compressed air.

Downstream filtration

CAC Fact Sheet #11 (May 2026) says coalescing filters remove lubricant and moisture, and adsorbent filters remove vaporous contaminants. In the Gardner Denver 2026 filter brochure, a Grade G filter leaves a maximum remaining oil aerosol content of 0.03 mg/m³ and a Grade H filter 0.01 mg/m³, both at 21 °C, while a Grade V activated carbon filter, preceded by Grade H, removes oil vapour to a maximum remaining oil content of <0.003 mg/m³ at 21 °C.

Ultra Controlo distributes and services Gardner Denver in Portugal, whose range includes compressed air filters, and supplies the ULTRAK activated carbon tower, whose datasheet gives a nominal residual oil vapour content below 0.003 mg/m³ and a pressure drop of 20 mbar when new and dry.

More questions

Is oil carryover the same as oil vapour?

Gardner Denver rates them separately: its Grade G and H filters by remaining oil aerosol content, and its Grade V activated carbon filter for oil vapour and hydrocarbon odour.

Can an oil-free compressor carry over oil?

Gardner Denver says oil-free compressors have no oil present in the compression chamber, and that oil-less compressors have no oil anywhere in the package.

Sources

Ultra Controlo figures come from its technical datasheets. Third-party facts were read at the source on the date shown.

Reviewed: · Ultra Controlo engineering · Markdown version

Related