Medical gas library

Oxygen and PSA

What equipment comes with each ULTRAOX model?

What equipment comes with each ULTRAOX model, from the aftercooler to the oxygen storage tank?

Short answer

The 2026 ULTRAOX datasheet tables list, for every model, an ULTRACOOL aftercooler, CTA filter chain, ULTRASEC dryer, air receiver, ULTRACON generator, oxygen process tank and storage tank, plus an ULTRAK tower and ULTRASEP separator in the ULTRAOX ST version.

The component tables of the two 2026 datasheets list, for each ULTRAOX model, the equipment between the compressor and the oxygen storage tank. The datasheets list these components; this page reports the lists and does not say what every plant contains. The table below follows the air through the plant.

Air side

ModelAftercoolerAir treatment chainRefrigeration dryerActivated carbon tower (ULTRAOX ST)Oil/water separator (ULTRAOX ST)Air receiver
ULTRAOX 30ULTRACOOL 1CTA 13ULTRASEC 6ULTRAK 2ULTRASEP 0270 L, 11 bar
ULTRAOX 50ULTRACOOL 1CTA 13ULTRASEC 7ULTRAK 3ULTRASEP 0500 L, 11 bar
ULTRAOX 70ULTRACOOL 2CTA 20ULTRASEC 8ULTRAK 4ULTRASEP 1500 L, 11 bar
ULTRAOX 90ULTRACOOL 2CTA 25ULTRASEC 9ULTRAK 8ULTRASEP 11,000 L, 11.5 bar
ULTRAOX 100ULTRACOOL 3CTA 25ULTRASEC 11ULTRAK 8ULTRASEP 11,000 L, 11.5 bar
ULTRAOX 120ULTRACOOL 3CTA 25ULTRASEC 11ULTRAK 9ULTRASEP 11,000 L, 11.5 bar
ULTRAOX 180ULTRACOOL 4CTA 25/1ULTRASEC 13ULTRAK 11ULTRASEP 21,000 L, 11.5 bar
ULTRAOX 260ULTRACOOL 5CTA 40ULTRASEC 14ULTRAK 12ULTRASEP 32,000 L, 11.5 bar
ULTRAOX 370ULTRACOOL 6CTA 40ULTRASEC 25ULTRAK 13ULTRASEP 32,000 L, 11.5 bar
ULTRAOX 440ULTRACOOL 8CTA 40/1ULTRASEC 27ULTRAK 14ULTRASEP 42 × 2,000 L, 11.5 bar
ULTRAOX 520ULTRACOOL 8CTA 40/1ULTRASEC 27ULTRAK 14ULTRASEP 42 × 2,000 L, 11.5 bar
ULTRAOX 560ULTRACOOL 8CTA 40/1ULTRASEC 27ULTRAK 14ULTRASEP 42 × 2,000 L, 11.5 bar
ULTRAOX 730ULTRACOOL 9CTA 50ULTRASEC 28ULTRAK 15ULTRASEP 43 × 2,000 L, 11.5 bar
ULTRAOX 820ULTRACOOL 9CTA 50/1ULTRASEC 29ULTRAK 16ULTRASEP 53 × 2,000 L, 11.5 bar
ULTRAOX 1120ULTRACOOL 10CTA 50/1ULTRASEC 30ULTRAK 17ULTRASEP 53 × 3,000 L, 11.5 bar
ULTRAOX 1640ULTRACOOL 12CTA 80ULTRASEC 32ULTRAK 19ULTRASEP 64 × 3,000 L, 11.5 bar

Oxygen side

ModelOxygen generatorOxygen process tankOxygen storage tank
ULTRAOX 30ULTRACON 4100 L, 11 bar200 L, 11 bar
ULTRAOX 50ULTRACON 5100 L, 11 bar200 L, 11 bar
ULTRAOX 70ULTRACON 6200 L, 11 bar270 L, 11 bar
ULTRAOX 90ULTRACON 7200 L, 11 bar500 L, 11 bar
ULTRAOX 100ULTRACON 8270 L, 11 bar500 L, 11 bar
ULTRAOX 120ULTRACON 9500 L, 11 bar1,000 L, 11.5 bar
ULTRAOX 180ULTRACON 10500 L, 11 bar1,000 L, 11.5 bar
ULTRAOX 260ULTRACON 111,000 L, 11.5 bar1,000 L, 11.5 bar
ULTRAOX 370ULTRACON 121,000 L, 11.5 bar1,000 L, 11.5 bar
ULTRAOX 440ULTRACON 132,000 L, 11.5 bar2,000 L, 11.5 bar
ULTRAOX 520ULTRACON 11 × 22,000 L, 11.5 bar2,000 L, 11.5 bar
ULTRAOX 560ULTRACON 142,000 L, 11.5 bar2,000 L, 11.5 bar
ULTRAOX 730ULTRACON 12 × 22,000 L, 11.5 bar2,000 L, 11.5 bar
ULTRAOX 820ULTRACON 152,000 L, 11.5 bar2,000 L, 11.5 bar
ULTRAOX 1120ULTRACON 14 × 22,000 L, 11.5 bar2,000 L, 11.5 bar
ULTRAOX 1640ULTRACON 15 × 22,000 L, 11.5 bar2 × 2,000 L, 11.5 bar

Tank pressures are maximum operating pressures. At 2,000 to 3,000 m the tables add 2 oxygen filtration systems and 2 flow measurement systems for ULTRAOX 1640. The ULTRAOX SC table lists the same values in the columns it has; it has no ULTRAK or ULTRASEP column.

What the ULTRAOX ST datasheet says each component does

  • ULTRACOOL aftercooler: lowers the temperature and dew point of the compressed air to protect the downstream dryers and filters; it is fully air-cooled and needs no water supply.
  • CTA air treatment chain (FF/MF/SMF/AK): filtration that removes particles, oil aerosols, vapours and gases from the compressed air.
  • ULTRASEC refrigeration dryer: removes moisture from the compressed air before oxygen generation.
  • ULTRAK activated carbon tower: adsorbs oil vapours and hydrocarbons before storage.
  • Air receiver: a compressed-air buffer tank that smooths pressure fluctuations and provides reserve capacity.
  • ULTRACON oxygen generator: the PSA generator of the plant; the table gives its model for each plant.
  • Oxygen process tank: stabilises the PSA-generated oxygen by smoothing pressure cycles before downstream treatment.
  • Oxygen storage tank: provides reserve oxygen capacity to meet peak demands and emergency needs.
  • ULTRASEP oil/water separator: separates oil residues from the water of the compressor condensate before drainage.

The datasheet also describes an oxygen filtration and sterilisation system, with precision filtration of sub-micron particles and autoclave-sterilisable media, and a flow measurement system with real-time and recorded readings; the datasheet table fields count one of each per plant, and two of each for ULTRAOX 1640 at 2,000 to 3,000 m. For the general chain, see what equipment makes up a PSA oxygen plant; for single components, see why a PSA plant needs an oxygen receiver, why it needs a dryer and what an activated carbon tower does.

More questions

Does the ULTRAOX SC table list the ULTRAK tower and the ULTRASEP separator?

No. The ULTRAOX SC components table in the 2026 datasheet has no ULTRAK or ULTRASEP column. The ULTRAOX ST table lists both for each model.

Is the compressor in the components table?

No. The compressor is in the model table: ULTRASCREW by altitude band for the ULTRAOX ST, as set out in ULTRAOX models compared.

Sources

Ultra Controlo figures come from its technical datasheets. Third-party facts were read at the source on the date shown.

Reviewed: · Ultra Controlo engineering · Markdown version