Oxygen and PSA
What equipment comes with each ULTRAOX model?
What equipment comes with each ULTRAOX model, from the aftercooler to the oxygen storage tank?
Short answer
The 2026 ULTRAOX datasheet tables list, for every model, an ULTRACOOL aftercooler, CTA filter chain, ULTRASEC dryer, air receiver, ULTRACON generator, oxygen process tank and storage tank, plus an ULTRAK tower and ULTRASEP separator in the ULTRAOX ST version.
The component tables of the two 2026 datasheets list, for each ULTRAOX model, the equipment between the compressor and the oxygen storage tank. The datasheets list these components; this page reports the lists and does not say what every plant contains. The table below follows the air through the plant.
Air side
| Model | Aftercooler | Air treatment chain | Refrigeration dryer | Activated carbon tower (ULTRAOX ST) | Oil/water separator (ULTRAOX ST) | Air receiver |
|---|---|---|---|---|---|---|
| ULTRAOX 30 | ULTRACOOL 1 | CTA 13 | ULTRASEC 6 | ULTRAK 2 | ULTRASEP 0 | 270 L, 11 bar |
| ULTRAOX 50 | ULTRACOOL 1 | CTA 13 | ULTRASEC 7 | ULTRAK 3 | ULTRASEP 0 | 500 L, 11 bar |
| ULTRAOX 70 | ULTRACOOL 2 | CTA 20 | ULTRASEC 8 | ULTRAK 4 | ULTRASEP 1 | 500 L, 11 bar |
| ULTRAOX 90 | ULTRACOOL 2 | CTA 25 | ULTRASEC 9 | ULTRAK 8 | ULTRASEP 1 | 1,000 L, 11.5 bar |
| ULTRAOX 100 | ULTRACOOL 3 | CTA 25 | ULTRASEC 11 | ULTRAK 8 | ULTRASEP 1 | 1,000 L, 11.5 bar |
| ULTRAOX 120 | ULTRACOOL 3 | CTA 25 | ULTRASEC 11 | ULTRAK 9 | ULTRASEP 1 | 1,000 L, 11.5 bar |
| ULTRAOX 180 | ULTRACOOL 4 | CTA 25/1 | ULTRASEC 13 | ULTRAK 11 | ULTRASEP 2 | 1,000 L, 11.5 bar |
| ULTRAOX 260 | ULTRACOOL 5 | CTA 40 | ULTRASEC 14 | ULTRAK 12 | ULTRASEP 3 | 2,000 L, 11.5 bar |
| ULTRAOX 370 | ULTRACOOL 6 | CTA 40 | ULTRASEC 25 | ULTRAK 13 | ULTRASEP 3 | 2,000 L, 11.5 bar |
| ULTRAOX 440 | ULTRACOOL 8 | CTA 40/1 | ULTRASEC 27 | ULTRAK 14 | ULTRASEP 4 | 2 × 2,000 L, 11.5 bar |
| ULTRAOX 520 | ULTRACOOL 8 | CTA 40/1 | ULTRASEC 27 | ULTRAK 14 | ULTRASEP 4 | 2 × 2,000 L, 11.5 bar |
| ULTRAOX 560 | ULTRACOOL 8 | CTA 40/1 | ULTRASEC 27 | ULTRAK 14 | ULTRASEP 4 | 2 × 2,000 L, 11.5 bar |
| ULTRAOX 730 | ULTRACOOL 9 | CTA 50 | ULTRASEC 28 | ULTRAK 15 | ULTRASEP 4 | 3 × 2,000 L, 11.5 bar |
| ULTRAOX 820 | ULTRACOOL 9 | CTA 50/1 | ULTRASEC 29 | ULTRAK 16 | ULTRASEP 5 | 3 × 2,000 L, 11.5 bar |
| ULTRAOX 1120 | ULTRACOOL 10 | CTA 50/1 | ULTRASEC 30 | ULTRAK 17 | ULTRASEP 5 | 3 × 3,000 L, 11.5 bar |
| ULTRAOX 1640 | ULTRACOOL 12 | CTA 80 | ULTRASEC 32 | ULTRAK 19 | ULTRASEP 6 | 4 × 3,000 L, 11.5 bar |
Oxygen side
| Model | Oxygen generator | Oxygen process tank | Oxygen storage tank |
|---|---|---|---|
| ULTRAOX 30 | ULTRACON 4 | 100 L, 11 bar | 200 L, 11 bar |
| ULTRAOX 50 | ULTRACON 5 | 100 L, 11 bar | 200 L, 11 bar |
| ULTRAOX 70 | ULTRACON 6 | 200 L, 11 bar | 270 L, 11 bar |
| ULTRAOX 90 | ULTRACON 7 | 200 L, 11 bar | 500 L, 11 bar |
| ULTRAOX 100 | ULTRACON 8 | 270 L, 11 bar | 500 L, 11 bar |
| ULTRAOX 120 | ULTRACON 9 | 500 L, 11 bar | 1,000 L, 11.5 bar |
| ULTRAOX 180 | ULTRACON 10 | 500 L, 11 bar | 1,000 L, 11.5 bar |
| ULTRAOX 260 | ULTRACON 11 | 1,000 L, 11.5 bar | 1,000 L, 11.5 bar |
| ULTRAOX 370 | ULTRACON 12 | 1,000 L, 11.5 bar | 1,000 L, 11.5 bar |
| ULTRAOX 440 | ULTRACON 13 | 2,000 L, 11.5 bar | 2,000 L, 11.5 bar |
| ULTRAOX 520 | ULTRACON 11 × 2 | 2,000 L, 11.5 bar | 2,000 L, 11.5 bar |
| ULTRAOX 560 | ULTRACON 14 | 2,000 L, 11.5 bar | 2,000 L, 11.5 bar |
| ULTRAOX 730 | ULTRACON 12 × 2 | 2,000 L, 11.5 bar | 2,000 L, 11.5 bar |
| ULTRAOX 820 | ULTRACON 15 | 2,000 L, 11.5 bar | 2,000 L, 11.5 bar |
| ULTRAOX 1120 | ULTRACON 14 × 2 | 2,000 L, 11.5 bar | 2,000 L, 11.5 bar |
| ULTRAOX 1640 | ULTRACON 15 × 2 | 2,000 L, 11.5 bar | 2 × 2,000 L, 11.5 bar |
Tank pressures are maximum operating pressures. At 2,000 to 3,000 m the tables add 2 oxygen filtration systems and 2 flow measurement systems for ULTRAOX 1640. The ULTRAOX SC table lists the same values in the columns it has; it has no ULTRAK or ULTRASEP column.
What the ULTRAOX ST datasheet says each component does
- ULTRACOOL aftercooler: lowers the temperature and dew point of the compressed air to protect the downstream dryers and filters; it is fully air-cooled and needs no water supply.
- CTA air treatment chain (FF/MF/SMF/AK): filtration that removes particles, oil aerosols, vapours and gases from the compressed air.
- ULTRASEC refrigeration dryer: removes moisture from the compressed air before oxygen generation.
- ULTRAK activated carbon tower: adsorbs oil vapours and hydrocarbons before storage.
- Air receiver: a compressed-air buffer tank that smooths pressure fluctuations and provides reserve capacity.
- ULTRACON oxygen generator: the PSA generator of the plant; the table gives its model for each plant.
- Oxygen process tank: stabilises the PSA-generated oxygen by smoothing pressure cycles before downstream treatment.
- Oxygen storage tank: provides reserve oxygen capacity to meet peak demands and emergency needs.
- ULTRASEP oil/water separator: separates oil residues from the water of the compressor condensate before drainage.
The datasheet also describes an oxygen filtration and sterilisation system, with precision filtration of sub-micron particles and autoclave-sterilisable media, and a flow measurement system with real-time and recorded readings; the datasheet table fields count one of each per plant, and two of each for ULTRAOX 1640 at 2,000 to 3,000 m. For the general chain, see what equipment makes up a PSA oxygen plant; for single components, see why a PSA plant needs an oxygen receiver, why it needs a dryer and what an activated carbon tower does.
More questions
Does the ULTRAOX SC table list the ULTRAK tower and the ULTRASEP separator?
No. The ULTRAOX SC components table in the 2026 datasheet has no ULTRAK or ULTRASEP column. The ULTRAOX ST table lists both for each model.
Is the compressor in the components table?
No. The compressor is in the model table: ULTRASCREW by altitude band for the ULTRAOX ST, as set out in ULTRAOX models compared.
Sources
- ULTRAOX ST datasheet, 2026 edition (components table and component descriptions)
- ULTRAOX SC datasheet, 2026 edition (components table)
Ultra Controlo figures come from its technical datasheets. Third-party facts were read at the source on the date shown.