Ultra Controlo Medical gas library

Pipeline systems

Which gases does a hospital pipeline system carry?

Which gases and services does a hospital medical gas pipeline system carry?

Short answer

Under ISO 7396-1 and NHS England's HTM 02-01, a hospital pipeline system can carry oxygen or oxygen 93, medical air, surgical air or nitrogen for driving tools, nitrous oxide and its 50/50 mixture with oxygen, carbon dioxide and medical vacuum. Anaesthetic gas scavenging is a separate disposal system covered by ISO 7396-2.

The services in ISO 7396-1

ISO 7396-1:2016, the international standard for pipeline systems for compressed medical gases and vacuum, covers oxygen, oxygen 93, nitrous oxide, medical air, carbon dioxide, gases for driving surgical tools and vacuum. Where every source delivers oxygen 93, the oxygen concentration in the pipeline may vary between 90% and 96%. Anaesthetic gas scavenging disposal systems are covered by ISO 7396-2, and units that blend oxygen and nitrogen into synthetic medical air or tool air by ISO 7396-3:2025.

The services in NHS England's HTM 02-01

HTM 02-01 (2026 edition) lists pipeline identification for these services, each with its own colour band and label:

ServiceMain useNominal pressure in HTM 02-01
Oxygen (O2)Patient oxygen supply400 kPa
Nitrous oxide (N2O)Anaesthesia400 kPa
Oxygen/nitrous oxide 50%/50%Labour, delivery and recovery rooms, among others400 kPa
Medical air (MA4)Driving ventilators and other respiratory uses400 kPa
Surgical air (SA7)Driving surgical tools700 kPa
Dental air (DA)Driving dental tools600 kPa
Medical vacuum (MV)Clinical suctionBelow atmospheric pressure
Carbon dioxide (CO2), surgical nitrogen (SN), oxygen/helium 21%/79%Specialist usesNot in Table 30
Anaesthetic gas scavenging (AGS) and dental vacuum (DV)Removal of waste anaesthetic gas; dental suctionBelow atmospheric pressure

HTM 02-01 also has a chapter on other medical gases: local supplies of liquid nitrogen, nitric oxide, heliox and carbon dioxide. Portugal's ACSS specification ET 03/2006 (2024 revision) sets the minimum number of outlets for oxygen, carbon dioxide, nitrous oxide, vacuum and medical air at 400 kPa and 700 kPa, counted, depending on the area, per bed, per room, per incubator, per treatment position or per resuscitation table.

What is changing

The 2026 HTM 02-01 reports that anaesthetic organisations have recommended that piped nitrous oxide should no longer be considered in modern anaesthetic practice, with a move to point-of-use cylinders. It also notes that surgical air use is declining as battery and electrically powered tools spread, and that the need for medical air and surgical air in each project is decided through its informed design process. Which services a hospital pipes is therefore a design decision.

Ultra Controlo designs and manufactures supply plants for several of these services: ULTRAOX PSA plants for oxygen at 94% (±1%) purity, ULTRAAR medical air plants, ULTRAVAC medical vacuum plants and ULTRASEG anaesthetic gas scavenging systems.

More questions

Is oxygen 93 piped in the same network as oxygen above 99%?

ISO 7396-1 covers supply systems that deliver a mixture of oxygen 93 and oxygen, with a concentration between 90% and above 99%. Portugal's ACSS recommends a separate or dedicated network for oxygen 93.

Is anaesthetic gas scavenging part of the medical gas pipeline?

It is treated separately: ISO 7396-2 covers anaesthetic gas scavenging disposal systems, while ISO 7396-1 covers compressed medical gases and vacuum.

Sources

Ultra Controlo figures come from its technical datasheets. Third-party facts were read at the source on the date shown.