Oxygen and PSA
Air-cooled vs water-cooled oxygen booster
Short answer
WHO's technical specifications of 31 December 2024 list a cylinder filling booster as air or water cooled, and suggest considering water cooling for warmer climates and throughput above about 15 m³/h; the US DOE sourcebook describes fan-and-fin air cooling and water jackets.
In WHO's cylinder filling station table the booster compressor is a reciprocating type, oil-free on the oxygen side, with cooling by air or by water. WHO's note says to consider water cooling for warmer climates and for a throughput capacity greater than about 15 m³/h. The US Department of Energy's compressed air sourcebook explains the cooling methods for air compressors, not oxygen boosters, so it is used here for the principle only.
Side by side
| Point | Air-cooled | Water-cooled |
|---|---|---|
| How the heat is removed (DOE sourcebook, air compressors) | Single-acting reciprocating compressors are typically air-cooled using a fan, with cooling air blown across finned surfaces on the outside of the cylinder | Larger, double-acting reciprocating air compressors have built-in cooling water jackets around the cylinders and in the cylinder heads |
| What WHO says for a filling booster (2024) | Listed as an option | To be considered for warmer climates and for throughput capacity greater than about 15 m³/h |
What else the sources say
- The DOE sourcebook says air or gas compression generates heat, that industrial air compressors that operate continuously generate substantial amounts of heat, and that compressor units are cooled with air, water and/or lubricant.
- For water cooling, it says the temperature of the inlet water and the design and cleanliness of the cooler can affect overall system performance and efficiency, and its maintenance checklist for water-cooled double-acting compressors includes checking cylinder jacket cooling water temperatures.
- In the same WHO table, the booster has an automatic shut-off when a maximum temperature of 204 °C (400 °F) is exceeded, and a visual alarm for abnormal temperature rise is recommended.
ULTRAFIL
The ULTRAFIL datasheet (2026) lists high temperature and overpressure shutdowns among the booster's key features and does not list a cooling type, so the cooling method is a point to put to the vendor in writing. See also what a cylinder filling station tender should specify and what operating conditions a booster should meet.
More questions
What cooling does WHO list for a cylinder filling booster?
Air cooled or water cooled, with water cooling to be considered for warmer climates and for throughput capacity greater than about 15 m³/h.
What affects the performance of a water-cooled compressor?
The DOE sourcebook says the temperature of the inlet water and the design and cleanliness of the cooler can affect overall system performance and efficiency.
Sources
- WHO, Technical specifications for health facility based medical oxygen systems (31 December 2024), section 1.2, cylinder filling station
- US Department of Energy, Improving Compressed Air System Performance: A Sourcebook for Industry, third edition
- ULTRAFIL datasheet, p. 2
Ultra Controlo figures come from its technical datasheets. Third-party facts were read at the source on the date shown.