AIGA 021/20 (EIGA Doc 13): oxygen pipeline and piping systems

AIGA 021/20, the Asia Industrial Gases Association’s revision of AIGA 021/12, is an international harmonised publication, originally EIGA Doc 13, whose scope is metal oxygen pipelines, distribution piping systems and gaseous oxygen piping on an air separation plant outside the coldbox, for gaseous oxygen up to 21 MPa.

What it is

AIGA says it published AIGA 021, Oxygen Pipeline and Piping Systems, as part of a programme of harmonisation of industry standards, jointly produced by members of the International Harmonisation Council and originally published as EIGA Doc 13 by the European Industrial Gases Association. The council’s members include the Asia Industrial Gases Association, the Compressed Gas Association, the European Industrial Gases Association and the Japan Industrial and Medical Gases Association, and each association’s technical content is identical, except for regional regulatory requirements and minor changes in formatting and spelling.

It is not law. AIGA says reference to or use of its publications is purely voluntary and not binding, that national laws supersede the practices it suggests, and that its recommendations apply only to installations begun after the publication date. It also says its publications are subject to periodic review and users are cautioned to obtain the latest edition.

Scope

The scope is limited to gaseous oxygen with a temperature range between -30 °C and 200 °C (-22 °F and 400 °F), pressures up to 21 MPa (3000 psi) and a dew point of -30 °C (-22 °F) or less depending on local conditions. The publication does not apply to oxygen cylinder filling plants, medical oxygen piping installations, coldbox internal piping, oxygen compressor units or liquid oxygen vaporisers, among other exclusions. Non-metal piping for oxygen-enriched gases is outside the scope and needs a specific risk assessment and precautions.

Oxygen purity in the definitions

  • Gaseous oxygen is defined as gas that contains greater than 23.5% oxygen by volume.
  • Low purity oxygen is gaseous oxygen that contains 35% or less oxygen by volume (23.5% to 35%).
  • Standard purity oxygen is defined as 99.5+% by volume, and the exemption pressures for alloys in section 4.3.1 are given for standard purity oxygen.

How it frames the hazard

The publication describes an oxygen system through the fire triangle of oxidiser, fuel and ignition source, and says the system fire hazard increases with increasing concentration, pressure, temperature and flowrate. It says pressure-velocity curves only address the particle impact ignition mechanism, so other ignition mechanisms should be evaluated, and that aluminium-based alloys shall not be used in gaseous oxygen piping systems outside the coldbox. For the fire risk of pipelines and the oxygen compatibility of plant parts, see the fire risk of oxygen pipelines, oxygen cleaning and which parts of a PSA plant must be oxygen compatible. The related industry guidance on 93% on-site oxygen is in EIGA Doc 195.

ULTRAOX VSA

The ULTRAOX VSA datasheet states that this Ultra Controlo industrial oxygen plant delivers oxygen at a concentration between 75% and 95% at 50 kPa, and that higher pressures can be achieved with an additional oxygen booster as part of the supply, on demand. The AIGA publication does not mention ULTRAOX VSA or any Ultra Controlo product, and this page does not state that any product or installation conforms to it. ULTRAOX VSA is an industrial line, not a medical oxygen plant.

More questions

Does AIGA 021/20 cover medical oxygen piping?

No. Its scope says the publication does not apply to medical oxygen piping installations or to oxygen cylinder filling plants.

Is AIGA 021/20 mandatory?

No. AIGA says reference to or use of its publications is purely voluntary and not binding, and that national laws supersede the practices it suggests.

Is AIGA 021/20 the same as EIGA Doc 13?

AIGA 021 was originally published as EIGA Doc 13, and AIGA says each association’s technical content is identical except for regional regulatory requirements and minor changes in formatting and spelling.