Medical gas library

Oxygen and PSA

Can a hospital replace liquid oxygen with a PSA plant?

Can a hospital switch from liquid oxygen deliveries to an on-site PSA plant, and what changes?

Short answer

A hospital can make an on-site PSA plant its main oxygen source instead of liquid oxygen where national rules allow it, but the switch changes the gas, from cryogenic oxygen of at least 99.5% to Oxygen 93 (90% to 96%), and moves responsibility for its quality from the gas supplier to the hospital.

Request a quote

What changes

Liquid oxygenOn-site PSA plant
GasCryogenic oxygen, at least 99.5% (Ph. Eur. monograph 0417)Oxygen 93: 90.0% to 96.0% oxygen (International Pharmacopoeia, 2025)
Where it is madeAlways off site, then stored in a tank at the hospital (WHO, 2020)On site, from ambient air (WHO, 2020; International Pharmacopoeia, 2025)
Who answers for qualityThe gas supplier, which needs a manufacturer's licence (AIGA 113/20, adopted from EIGA Doc 195)Qualified personnel of the healthcare facility, normally the head pharmacist (AIGA 113/20)
ElectricityNot needed: the tank feeds the pipeline by self-vaporisation (WHO, 2020)Needed: NHS England's HTM 02-01 (2026) asks for all PSA components to be connected to the essential electrical supply
LossesContinuous vaporisation, as much as about 5% a day depending on the tank (WHO, 2023)Part of the product gas regenerates the sieves and is allowed for when sizing the plant (HTM 02-01)

Where it is allowed

National rules decide. NHS England's HTM 02-01 (2026) says PSA systems may serve as an alternative to liquid oxygen in certain circumstances, but should only be considered where geographical or environmental constraints prevent liquid oxygen or compressed gas supply, such as remote or off-shore locations, and that agreement from the Medical Gas Safety Group (MGSG) should also be sought. Portugal's ACSS specification ET 03/2006 (revised June 2024) recommends starting Oxygen 93 in the outpatient structures of small hospitals and in primary care units, and requires a medicinal oxygen source to be provided as well as the three Oxygen 93 sources, available whenever needed. Since 2 December 2025, a Portuguese health institution that makes medical gases with medical devices for clinical use on its own premises must also notify INFARMED in advance and designate a responsible pharmacist (Deliberação n.º 1425/2025); see Is Oxygen 93 a medicine in Portugal?

What the hospital keeps or adds

  • Three sources: HTM 02-01 states that all medical gas supplies should comprise primary, secondary and tertiary sources of supply, so the PSA plant is one of three. See what backup to keep with a PSA plant.
  • The old supply as a reserve: if liquid or cylinder oxygen stays connected, ISO 7396-1:2016 states that a supply combining Oxygen 93 and oxygen sources can vary between 90% and above 99%, while HTM 02-01 asks for an emergency reserve manifold working with a PSA to supply the same concentration as the PSA and notes that cylinders from a gas supplier are above 99%.
  • Equipment: the ACSS specification asks for the compatibility of Oxygen 93 with the medical equipment connected to oxygen outlets to be guaranteed, especially their calibration.
  • Backup cylinders and power: WHO interim guidance (April 2020) calls it best practice to also keep cylinders as a backup supply for a PSA plant, and Global Fund guidance asks for appropriately sized backup power; see does a PSA plant need a generator or UPS.

Connecting an ULTRAOX plant

The ULTRAOX SC datasheet states that the existing installation can be kept and the plant connected to it as a new source of oxygen supply. ULTRAOX SC and ST plants deliver oxygen at 93% ± 3% and 6 bar, according to their datasheets. For industrial sites, not hospitals, the ULTRAOX VSA datasheet states that the plant can replace existing cryogenic systems with liquid oxygen tanks or work as the main source of supply; see industrial VSA oxygen plants.

More questions

Can the liquid oxygen tank stay as a backup?

Rules differ: ISO 7396-1:2016 covers supply systems that combine Oxygen 93 and oxygen sources, with 90% to above 99% in the pipeline, while HTM 02-01 asks for the reserve to supply the same concentration as the PSA.

Does a PSA plant end all oxygen deliveries?

No. WHO interim guidance (April 2020) calls it best practice to also keep cylinders as a backup supply for a PSA plant.

Sources

Ultra Controlo figures come from its technical datasheets. Third-party facts were read at the source on the date shown.

Reviewed: · Ultra Controlo engineering · Markdown version