Medical gas library

Medical air

How does a refrigerated compressed air dryer work?

Short answer

According to the US Department of Energy sourcebook (2016), a refrigerated dryer cools compressed air so that its moisture condenses and is removed by a separator and drain; the Compressed Air Challenge Fact Sheet #11 (May 2026) gives refrigerant-type dryers a pressure dew point of 35 to 39 °F.

The third edition (2016) of the sourcebook Improving Compressed Air System Performance, published by the US Department of Energy with the Compressed Air Challenge, explains why the air is dried at all: air leaving an aftercooler and moisture separator is typically saturated, and further cooling in the distribution piping makes more moisture condense, with corrosion and contamination of point-of-use processes as a result.

Inside a non-cycling dryer

In a non-cycling refrigerated dryer the air is cooled in a refrigerant-to-air heat exchanger. The cooling comes from the evaporation of a liquid refrigerant, which makes the moisture in the air condense; the water is then removed by a separator and drain, and a hot gas bypass valve controls the temperature of the air leaving the evaporator. The sourcebook says the dryer lowers the dew point of the air to about the temperature of the air leaving the refrigerant evaporator.

Most refrigerated dryers also have a pre-cooler/reheater, an air-to-air heat exchanger in which the hot incoming air reheats the dried air. This lowers the temperature of the incoming air before the main heat exchanger, reducing the heat load on the refrigerant system, and the reheating prevents condensation on the outside of the compressed air piping in warm, humid environments.

Cycling dryers

Cycling dryers cool the compressed air indirectly, through a thermal storage medium such as a heat sink, thermal mass or chilled media. One or two thermostats shut off the refrigerant compressor when it is not needed, saving energy, and the storage medium prevents rapid cycling of the refrigerant compressor. The Compressed Air Challenge Fact Sheet #11 (May 2026) adds that some refrigerant-type dryers can cycle on and off based on air flow, which may save energy.

What it achieves and what it costs

The 2026 fact sheet describes refrigerant-type dryers as the most common type, with a pressure dew point of 35 to 39 °F that is acceptable for many applications. In addition to the pressure drop across the dryer, usually 3 to 5 psid, the energy to run the refrigerant compressor must be considered. The 2016 sourcebook adds that refrigerant-type dryers, cycling and non-cycling, are not recommended in sub-freezing ambient temperatures, because the moisture in the compressed air can freeze and damage the dryer.

ISO 7183:2007, Compressed-air dryers, Specifications and testing, covers refrigeration dryers together with adsorption and membrane dryers. It specifies the performance data that are necessary to state for a dryer and identifies test methods for parameters that include pressure dew point and flow rate.

ULTRASEC

The ULTRASEC datasheet describes an aluminium heat exchanger designed for drying at inlet air temperatures up to 70 °C, a maximum compressed air inlet temperature of 100 °C for the ULTRASEC-HT version, a hot gas bypass valve designed to provide a constant dew point, a digital temperature indicator and a condensate drain with electronic control. Ultra Controlo supplies the ULTRASEC refrigeration dryer.

More questions

Can a refrigerated dryer run in freezing conditions?

The US Department of Energy sourcebook (2016) says refrigerant-type dryers, cycling and non-cycling, are not recommended in sub-freezing ambient temperatures, because the moisture in the compressed air can freeze and damage the dryer.

What does a refrigerated dryer cost to run?

The Compressed Air Challenge Fact Sheet #11 (May 2026) says the energy to run the refrigerant compressor must be considered in addition to the pressure drop across the dryer, usually 3 to 5 psid.

Sources

Ultra Controlo figures come from its technical datasheets. Third-party facts were read at the source on the date shown.

Reviewed: · Ultra Controlo engineering · Markdown version