Ultra Controlo Medical gas library

Medical air

ULTRASEC: specifications and models

ULTRASEC is the Ultra Controlo refrigeration air dryer with an aluminium heat exchanger and a hot gas bypass for a constant dew point.

The table covers single phase and three phase sizes.

Key facts from the datasheet

  • ULTRASEC is a refrigeration dryer.
  • It uses an aluminium heat exchanger for inlet air up to 70 °C.
  • Maximum inlet temperature: ULTRASEC standard 70 °C.
  • Maximum inlet temperature: ULTRASEC-HT 100 °C.
  • A hot gas bypass valve keeps the dew point constant.
  • It has a digital temperature indicator and an electronically controlled condensate drain.

Models

MODELFLOW-RATE (m3/h)FLOW-RATE (l/min)FLOW-RATE (scfm)POWER SUPPLY (Ph/Volt/Fr)CONNECTIONS (Ø)DIMENSIONS (mm) ADIMENSIONS (mm) BDIMENSIONS (mm) CWEIGHT (kg)
USL 121350121/230/50-60G 1/2" BSP-F34542074028
USL 233550191/230/50-60G 1/2" BSP-F34542074029
USL 351850301/230/50-60G 1/2" BSP-F34542074031
USL 4721200421/230/50-60G 1/2" BSP-F34542074034
USL 51081800641/230/50-60G 1"BSP-F34542074036
USL 61382300811/230/50G 1"BSP-F34542074037
USL 718631001091/230/50G 1.1/4"BSP-F48545582546
USL 824040001411/230/50G 1.1/4"BSP-F48545582550
USL 933055001941/230/50G 1.1/4"BSP-F55558082555
USL 1037262002191/230/50G 1.1/4"BSP-F55558082563
USL 1148681002861/230/50G 2" BSP-F55562597592
USL 12630105003711/230/50G 2" BSP-F55562597594
USL 13750125004411/230/50G 2.1/2" BSP-F6657251105141
USL 14870145005121/230/50G 2.1/2" BSP-F6657251105150
USL 15960160005651/230/50G 2.1/2" BSP-F6657251105161
USL 1633055001943/400/50G 1.1/2"BSP-F55558088572
USL 1737262002193/400/50G 1.1/2"BSP-F55558088580
USL 1848681002863/400/50G 2" BSP-F555625975108
USL 19630105003713/400/50G 2" BSP-F555625975110
USL 20750125004413/400/50G 2.1/2" BSP-F6657251105158
USL 21870145005123/400/50G 2.1/2" BSP-F6657251105160
USL 22960160005653/400/50G 2.1/2" BSP-F6657251105170
USL 231080180006363/400/50DN 80-PN 1679010001465240
USL 241260210007423/400/50DN 80-PN 1679010001465242
USL 251500250008833/400/50DN 80-PN 1679010001465275
USL 2618003000010603/400/50DN 80-PN 1679010001465276
USL 2722083680013003/400/50DN 80-PN 1679010001465311
USL 2824004000014133/400/50DN 100-PN 16113512051750463
USL 2930005000017663/400/50DN 100-PN 16113512051750538
USL 3036006000021193/400/50DN 100-PN 16113512051750540
USL 3144167360026003/400/50DN 100-PN 16113512051750612
USL 3254009000031783/400/50DN 150-PN 16130017501810830
USL 33662411040039003/400/50DN 150-PN 16130017501810940
USL 34720012000042383/400/50DN 200-PN 161400220018701055
USL 35883214720052003/400/50DN 200-PN 161400220018701200
USL 361080018000065373/400/50DN 200-PN 161450216524301650
USL 371324822080077693/400/50DN 200-PN 161450216524301750
USL 381440024000084763/400/50DN 250-PN 161450245524551950
USL 3917664294400105943/400/50DN 250-PN 161450245524552100

Values as printed in the Ultra Controlo datasheet. Ultra Controlo engineering confirms the configuration for each project.

Sources

Ultra Controlo figures come from its technical datasheets. Third-party facts were read at the source on the date shown.

Reviewed: · Ultra Controlo engineering · Markdown version