Medical air
ULTRAAR SC: specifications and models
ULTRAAR SC is a medical air plant built on oil-free ULTRACECO SC scroll compressors, with air treatment, dryers, receivers and pressure reduction sets with sterile filters.
It is sold in simplex and duplex versions with different skid arrangements.
Key facts from the datasheet
- ULTRAAR is built to EN ISO 7396-1 and fulfils HTM 02.
- ULTRAAR is manufactured under an ISO 13485 quality management system.
- Receivers are vertical, from 0.2 to 6 m3.
- The ULTRAAR SC uses totally oil-free ULTRACECO SC scroll (spiral) compressors.
- A remote monitoring system is available 24 hours.
- Particles are below 1 µm.
- Oil in fluid phase is exempt.
- CO2 is below 500 ppm.
- CO is below 5 ppm.
- SO2 is below 1 ppm.
- NOx is below 2 ppm.
- The working dew point is minus 46 °C.
- The maximum dew point is minus 70 °C.
Models
| MODEL ULTRACECO SC | PRESSURE (bar) | POWER (kW) | POWER (Hp) | l/min | SKIDS | CONFIGURATION |
|---|---|---|---|---|---|---|
| SC 1 - 8 | 8 | 1,5 | 2 | 160 | 1 SKID | SIMPLEX |
| SC 2 - 8 | 8 | 2,2 | 3 | 240 | 1 SKID | SIMPLEX |
| SC 2 - 10 | 10 | 2,2 | 3 | 200 | 1 SKID | SIMPLEX |
| SC 4 - 8 | 8 | 4 | 5,5 | 400 | 1 SKID | SIMPLEX |
| SC 5 - 8 | 8 | 5,5 | 7,5 | 600 | 1 SKID | SIMPLEX |
| SC 5 - 10 | 10 | 5,5 | 7,5 | 440 | 1 SKID | SIMPLEX |
| SC 7 - 8 | 8 | 7,5 | 10 | 850 | 1 SKID | SIMPLEX |
| SC 7 - 10 | 10 | 7,5 | 10 | 680 | 1 SKID | SIMPLEX |
| SC 21-8 | 8 | 3 | 4 | 320 | 2 SKIDS | SIMPLEX |
| SC 22-8 | 8 | 4,4 | 6 | 480 | 2 SKIDS | SIMPLEX |
| SC 22-10 | 10 | 4,4 | 6 | 400 | 2 SKIDS | SIMPLEX |
| SC 24-8 | 8 | 8 | 11 | 800 | 2 SKIDS | SIMPLEX |
| SC 25-8 | 8 | 11 | 15 | 1200 | 2 SKIDS | SIMPLEX |
| SC 25-10 | 10 | 11 | 15 | 880 | 2 SKIDS | SIMPLEX |
| SC 13-8 | 8 | 13 | 17,5 | 1450 | 2 SKIDS | SIMPLEX |
| SC 13-10 | 10 | 13 | 17,5 | 1120 | 2 SKIDS | SIMPLEX |
| SC 27-8 | 8 | 15 | 20 | 1700 | 2 SKIDS | SIMPLEX |
| SC 27-10 | 10 | 15 | 20 | 1360 | 2 SKIDS | SIMPLEX |
| SC 31-8 | 8 | 4,5 | 6 | 480 | 3 SKIDS | SIMPLEX |
| SC 32-8 | 8 | 6,6 | 9 | 720 | 3 SKIDS | SIMPLEX |
| SC 32-10 | 10 | 6,6 | 9 | 600 | 3 SKIDS | SIMPLEX |
| SC 34-8 | 8 | 12 | 16 | 1200 | 3 SKIDS | SIMPLEX |
| SC 35-8 | 8 | 16,5 | 22 | 1800 | 3 SKIDS | SIMPLEX |
| SC 35-10 | 10 | 16,5 | 22 | 1320 | 3 SKIDS | SIMPLEX |
| SC 37-8 | 8 | 22,5 | 30 | 2550 | 3 SKIDS | SIMPLEX |
| SC 37-10 | 10 | 22,5 | 30 | 2040 | 3 SKIDS | SIMPLEX |
| MODEL ULTRACECO SC | PRESSURE (bar) | POWER (kW) | POWER (Hp) | l/min | SKIDS | CONFIGURATION |
|---|---|---|---|---|---|---|
| SC 1-8 | 8 | 3 | 4 | 320 | 1 SKID | DUPLEX |
| SC 2-8 | 8 | 4,4 | 6 | 480 | 1 SKID | DUPLEX |
| SC 2-10 | 10 | 4,4 | 6 | 400 | 1 SKID | DUPLEX |
| SC 4-8 | 8 | 8 | 11 | 800 | 1 SKID | DUPLEX |
| SC 5-8 | 8 | 11 | 15 | 1200 | 1 SKID | DUPLEX |
| SC 5-10 | 10 | 11 | 15 | 880 | 1 SKID | DUPLEX |
| SC 7-8 | 8 | 15 | 20 | 1700 | 1 SKID | DUPLEX |
| SC 7-10 | 10 | 15 | 20 | 1360 | 1 SKID | DUPLEX |
| SC 21-8 | 8 | 6 | 8 | 640 | 2 SKIDS | DUPLEX |
| SC 22-8 | 8 | 8,8 | 12 | 960 | 2 SKIDS | DUPLEX |
| SC 22-10 | 10 | 8,8 | 12 | 800 | 2 SKIDS | DUPLEX |
| SC 24-8 | 8 | 16 | 22 | 1600 | 2 SKIDS | DUPLEX |
| SC 25-8 | 8 | 22 | 30 | 2400 | 2 SKIDS | DUPLEX |
| SC 25-10 | 10 | 22 | 30 | 1760 | 2 SKIDS | DUPLEX |
| SC 13-8 | 8 | 26 | 35 | 2900 | 2 SKIDS | DUPLEX |
| SC 13-10 | 10 | 26 | 35 | 2240 | 2 SKIDS | DUPLEX |
| SC 27-8 | 8 | 30 | 40 | 3400 | 2 SKIDS | DUPLEX |
| SC 27-10 | 10 | 30 | 40 | 2720 | 2 SKIDS | DUPLEX |
| SC 31-8 | 8 | 9 | 12 | 960 | 3 SKIDS | DUPLEX |
| SC 32-8 | 8 | 13,2 | 18 | 1440 | 3 SKIDS | DUPLEX |
| SC 32-10 | 10 | 13,2 | 18 | 1200 | 3 SKIDS | DUPLEX |
| SC 34-8 | 8 | 24 | 32 | 2400 | 3 SKIDS | DUPLEX |
| SC 35-8 | 8 | 33 | 44 | 3600 | 3 SKIDS | DUPLEX |
| SC 35-10 | 10 | 33 | 44 | 2640 | 3 SKIDS | DUPLEX |
| SC 37-8 | 8 | 45 | 60 | 5100 | 3 SKIDS | DUPLEX |
| SC 37-10 | 10 | 45 | 60 | 4080 | 3 SKIDS | DUPLEX |
Values as printed in the Ultra Controlo datasheet. Ultra Controlo engineering confirms the configuration for each project.
Standards cited in the datasheet
- EN ISO 7396-1
- HTM 02
- ISO 13485
- European Pharmacopoeia
Sources