Medical gas library

Oxygen and PSA

Low-pressure vs high-pressure oxygen boosters

Short answer

The Global Fund briefing note (4 March 2025) describes a medium pressure booster that raises oxygen from 4 to 6 bar up to 11 to 12 bar for piping, and WHO (2023) a high-pressure booster that raises it from 3 to 6 bar to up to 200 bar to fill cylinders.

The sources use different names for boosters that do different jobs. The Global Fund (2025) says a medium pressure booster can be added where national standards require piping above 6 bar, and it also speaks of a high pressure booster that fills cylinders. WHO (2023) calls the cylinder-filling device a booster compressor or high-pressure booster, and AIGA 113/20 calls it a high pressure compressor. The Ultra Controlo ULTRALOBO LPT datasheet describes its boosters as low-pressure.

Side by side

Booster for the pipelineBooster for cylinders
Job described in the sourcesRaises oxygen to the pipeline pressure: where national standards require piping above 6 bar (Global Fund, 2025), or for a double-stage pipeline system (AIGA 113/20)Fills high-pressure cylinders: WHO (2023) defines a cylinder filling station as a booster compressor and a cylinder filling ramp
Pressure in the sources4 to 6 bar up to 11 to 12 bar (Global Fund, 2025); a nominal pipeline pressure of 8 to 9 bar(g) in a double-stage system (AIGA 113/20)3 to 6 bar up to 200 bar (WHO, 2023); re-filling reserve vessels up to 200 bar(g), depending on national regulations (AIGA 113/20)
Name the source usesMedium pressure booster (Global Fund); booster compressor (AIGA 113/20)High pressure booster (Global Fund); booster compressor or high-pressure booster (WHO); high pressure compressor (AIGA 113/20)
OilThe Global Fund lists an additional oil-free oxygen booster compressor for VPSA and VSA distributionWHO (2023): must be an oil-free compressor
Ultra Controlo datasheetULTRALOBO LPT: ULTRACECO LPT low-pressure boosters, a completely oil-free system, all parts in contact with oxygen in AISI 316 stainless steel, and a model table with a 5 bar inlet and a 10 to 12 bar maximum outletULTRACECO HP: oil-free, suitable for compressing oxygen in 170/200 bar cylinders. ULTRACECO HPT: without oil, optionally up to 3,000 PSI (207 bar g). ULTRACECO HPX: oil-free

The figures come from different documents and describe different equipment, so they are not a like-for-like comparison. For the ULTRALOBO LPT, the datasheet table gives the inlet and maximum outlet of each model; see the ULTRALOBO LPT range. For when a PSA plant needs either kind, see does a PSA plant need a booster; for the cylinder side, see ULTRACECO HP, HPT and HPX compared.

More questions

Is a medium pressure booster the same as a low-pressure booster?

The documents use different names: the Global Fund note says medium pressure booster and the ULTRALOBO LPT datasheet says low-pressure boosters. Each name is used here with the document that uses it.

Does a booster that fills cylinders have to be oil-free?

WHO (2023) says the booster compressor, also known as a high-pressure compressor, must be an oil-free compressor.

Sources

Ultra Controlo figures come from its technical datasheets. Third-party facts were read at the source on the date shown.

Reviewed: · Ultra Controlo engineering · Markdown version

Related