Medical gas library

Industry

Particulate filter vs coalescing filter: what each one removes

Short answer

The Compressed Air Challenge Fact Sheet #11 (May 2026) describes particulate filters as removing solid particles and coalescing filters as removing lubricant and moisture, and recommends a coalescing filter before a desiccant dryer and a particulate filter after it, to remove desiccant fines.

The test methods for compressed air filters are in the ISO 12500 series; see ISO 12500: test methods for compressed air filters.

One range, three grades

Gardner Denver, GDF Series and GDWS Range filter brochure, pp. 5 and 6
Gardner Denver GDF gradeWhat the manufacturer says it removesDrain
Grade P, dust filtrationDust particles down to 1 micronManual unloader
Grade G, general purpose protectionParticles down to 0.1 micron, including coalesced liquid, water and oil; maximum remaining oil aerosol content of 0.03 mg/m³ at 21 °CInternal float drain
Grade H, high efficiencyParticles down to 0.01 micron, including water and oil aerosols; maximum remaining oil aerosol content of 0.01 mg/m³ at 21 °C; to be preceded by a Grade G filterInternal float drain

In the brochure, grades G and H are rated both for particle size and for remaining oil aerosol, while Grade P is rated for dust particles only. The manufacturer's brochure says the range provides air as defined by ISO 8573-1:2010 and is certified by a third party under ISO 12500-1.

Where each one goes

The 2026 fact sheet places a coalescing-type filter before a desiccant-type dryer, to prevent fouling of the desiccant bed, and a particulate filter after it to remove desiccant fines, and says additional filtration may be needed for specific end uses. Gardner Denver's brochure adds a water separator before a coalescing filter, to protect it against bulk liquid contamination.

Pressure drop and element changes

The fact sheet says filtration only to the level required by each compressed air application minimises pressure drop and the resulting energy consumption, and that elements should be replaced as indicated by pressure differential, and at least annually. Gardner Denver's filter brochure describes a pressure drop indicator that monitors the efficiency of the filter and indicates when the pressure drop is getting too high and element replacement is recommended.

Ultra Controlo distributes and services Gardner Denver in Portugal; see Gardner Denver compressors in Portugal.

More questions

Which filter goes after a desiccant dryer?

The Compressed Air Challenge Fact Sheet #11 (May 2026) recommends a particulate filter after a desiccant-type dryer to remove desiccant fines.

How often should filter elements be changed?

The same fact sheet says elements should be replaced as indicated by pressure differential, and at least annually, to minimise pressure drop and energy consumption.

Sources

Ultra Controlo figures come from its technical datasheets. Third-party facts were read at the source on the date shown.

Reviewed: · Ultra Controlo engineering · Markdown version

Related