Which filters does a compressed air system need?

Which filters does an industrial compressed air system need, and in what order?

Short answer

The Compressed Air Challenge Fact Sheet #11 (May 2026) names particulate filters for solid particles, coalescing filters for lubricant and moisture and adsorbent filters for vaporous contaminants, recommends a coalescing filter before a desiccant dryer and a particulate filter after it, and says to filter only to the level each application requires.

The fact sheet says filters downstream of the compressor are generally required to remove contaminants such as particulates, condensate and lubricant, and that additional filtration may be needed for specific end uses. CAC Fact Sheet #5 (May 2026) adds point-of-use filters, regulators and lubricators, which ensure a tool receives a clean, lubricated supply of air at the proper pressure.

In what order

Gardner Denver, a brand that Ultra Controlo distributes and services in Portugal, publishes the sequence for its GDWS water separators and GDF filter grades:

Source: Gardner Denver filter brochure, GDF Series and GDWS Range
StageWhat Gardner Denver says it removesPosition Gardner Denver gives
Water separator (GDWS)Bulk liquids such as condensate, water and liquid oil, by directional and centrifugal separationBefore a coalescing filter
Grade G, general purposeParticles down to 0.1 micron, including coalesced liquid, water and oil, to a maximum remaining oil aerosol content of 0.03 mg/m³ at 21 °CNot stated
Grade H, high efficiencyParticles down to 0.01 micron, including water and oil aerosols, to a maximum remaining oil aerosol content of 0.01 mg/m³ at 21 °CAfter grade G
Grade V, activated carbonOil vapour and hydrocarbon odour, to a maximum remaining oil content of <0.003 mg/m³ at 21 °CAfter grade H
Grade P, dustDust particles down to 1 micronNot stated

Around a desiccant dryer, CAC Fact Sheet #11 recommends a coalescing filter before it, to prevent fouling of the desiccant bed, and a particulate filter after it, to remove desiccant fines. For the ULTRAK activated carbon tower, the datasheet says a coalescing filter is required upstream and a 1 μm dust filter is recommended downstream, to intercept any residue from the activated carbon.

Pressure drop and element changes

Filtration only to the level required by each application minimises pressure drop and energy consumption, CAC Fact Sheet #11 says, and elements should be replaced as indicated by pressure differential, and at least annually. Gardner Denver says its pressure drop indicator shows when element replacement is recommended, that its filter range is certified by a third party under ISO 12500-1.

Ultra Controlo distributes and services Gardner Denver in Portugal, whose range includes compressed air filters, and supplies the ULTRADRY adsorption dryer, whose datasheet lists a coalescing filter at the inlet and a dust filter at the outlet.

More questions

How often should filter elements be changed?

CAC Fact Sheet #11 (May 2026) says elements should be replaced as indicated by pressure differential, and at least annually, to minimise pressure drop and energy consumption.

Why fit a water separator before a coalescing filter?

Gardner Denver says a water separator installed before a coalescing filter gives added protection against bulk liquid contamination, enabling the filter to operate more efficiently.

Sources

Ultra Controlo figures come from its technical datasheets. Third-party facts were read at the source on the date shown.

Reviewed: · Ultra Controlo engineering · Markdown version