Medical gas library

Medical air

ULTRASEC vs ULTRADRY: refrigeration or adsorption dryer?

Short answer

According to the Ultra Controlo datasheets, ULTRASEC is a refrigeration dryer for inlet air up to 70 °C (100 °C for ULTRASEC-HT), while ULTRADRY is an adsorption dryer with a pressure dew point range of −40 °C to −70 °C, working at 4 to 16 bar g.

The two dryers use different technologies. The US DOE sourcebook (2016) says the refrigerant dryer is the most commonly used dryer in industry, with relatively low initial and operating costs, and that it lowers the dew point to about the temperature of the air leaving the refrigerant evaporator, which should not go below 32 °F to avoid freezing. It describes the regenerative desiccant dryer as one in which a porous desiccant adsorbs the moisture, normally in two towers, one drying while the other is regenerated, with molecular sieve added as the final drying agent where very low dew points are required.

Side by side

ULTRASECULTRADRY
TechnologyRefrigeration dryer with an aluminium heat exchangerAdsorption dryer with desiccant in cartridges
Dew point in the datasheetNo figure; a hot gas bypass valve is designed to provide a constant dew pointPressure dew point range of −40 °C to −70 °C; the table values are given at −40 °C
Inlet air temperatureMaximum 70 °C (ULTRASEC standard) or 100 °C (ULTRASEC-HT)Minimum +5 °C, maximum +50 °C; table values assume +35 °C inlet and 7 bar g
Operating pressureNot stated in the datasheetMinimum 4 bar g, maximum 16 bar g
FiltersNot part of the datasheet descriptionCoalescing filter at the inlet and dust filter at the outlet
Drain and controlsDigital temperature indicator and condensate drain with electronic controlMicroprocessor control tells the operator when to replace the filter elements
Range in the datasheetUSL 1 to USL 39, 21 to 17664 m³/hTable in the datasheet; see the ULTRADRY page

The ULTRASEC table does not state the inlet conditions of its flow rates. The DOE sourcebook says dryer ratings usually are based on standard inlet conditions, commonly called the three 100s (100 psig, 100 °F inlet and 100 °F ambient), and that deviations affect the capacity of a dryer; most manufacturers provide correction factors. Ask for them in writing, for either dryer.

Which one for which dew point

Start from the dew point the process or the specification requires. The DOE sourcebook says drying compressed air beyond the required pressure dew point results in unnecessary energy and costs. It says a pressure dew point of between 35 and 40 °F can usually be obtained with a refrigerated dryer, and Compressed Air Challenge Fact Sheet #11 (May 2026) gives 35 to 39 °F for refrigerant-type dryers, which it calls acceptable for many applications, and says twin tower desiccant-type dryers are the most effective in the removal of moisture and typically are rated at a pressure dew point of −40 °F. These are general figures from the two sources, not figures for ULTRASEC or ULTRADRY.

Energy

The ULTRASEC datasheet says the estimated power consumption for an increase of 1 bar on the compressor is about 7% of the installed motor power, and presents low pressure drop as a way to lower energy consumption. Fact Sheet #11 says that for a refrigerant-type dryer the energy to run the refrigerant compressor must be considered besides the pressure drop across the dryer, and that for a twin tower desiccant dryer the purge air energy loss must be considered. The ULTRADRY table lists a compressed air consumption for each model; this page gives no percentage.

For the dryer types in general see dryers and filters for industrial compressed air, and for sizing see how a compressed air dryer is sized.

More questions

What dew point does an ULTRASEC give?

The ULTRASEC datasheet gives no dew point figure. It says a hot gas bypass valve is designed to provide a constant dew point at different pressure loading conditions.

Does an adsorption dryer need filters?

Fact Sheet #11 (May 2026) recommends a coalescing filter before a desiccant-type dryer and a particulate filter after it. The ULTRADRY datasheet lists a coalescing filter at the inlet and a dust filter at the outlet.

Sources

Ultra Controlo figures come from its technical datasheets. Third-party facts were read at the source on the date shown.

Reviewed: · Ultra Controlo engineering · Markdown version