Medical gas library

Oxygen and PSA

ULTRAOX 260: 26.2 Nm³/h PSA oxygen plant

According to the 2026 ULTRAOX SC and ULTRAOX ST datasheets, the ULTRAOX 260 is listed at 26.2 Nm³/h of oxygen at 93% ± 3% purity, with an ULTRACON 11 generator and a maximum daily filling capacity of 84 cylinders (50 L at 150 bar).

In the model tables of the ULTRAOX SC and ULTRAOX ST datasheets, the 260 sits between the ULTRAOX 180 (18.2 Nm³/h) and the ULTRAOX 370 (36.5 Nm³/h). The two tables list the same oxygen flow, daily filling capacity and oxygen generator for the two versions.

Datasheet values

ULTRAOX 260Value in the 2026 datasheets
Oxygen flow26.2 Nm³/h
Max. daily filling capacity84 cylinders (50 L at 150 bar)
Oxygen purity93% ± 3%
Oxygen generatorULTRACON 11
LayoutSimplex
VersionsULTRAOX SC and ULTRAOX ST, the same flow in both

The ULTRAOX product page describes its size match as indicative, from the datasheet, with Ultra Controlo engineers confirming the configuration for the site.

Compressor by altitude band

The ULTRAOX ST table lists an ULTRASCREW compressor for each altitude band: ULTRASCREW 37 at 0 to 1,000 m, ULTRASCREW 45 at 1,000 to 2,000 m and ULTRASCREW 55 at 2,000 to 3,000 m. The oxygen flow stays at 26.2 Nm³/h in all three bands.

The ULTRAOX SC table does not list the compressor of this model; its notes say that compressor data for the other models is available on request.

The ULTRAOX ST datasheet states that the power and pressure of the compressor can vary with the service conditions required for the facility. Ultra Controlo engineering confirms the configuration for each project.

What the tables list with the ULTRAOX 260

The components tables of the two datasheets list the following for this model. The ULTRAOX SC table has no column for the ULTRAK tower or the ULTRASEP separator.

ComponentListed for the ULTRAOX 260
AftercoolerULTRACOOL 5
Air treatment chainCTA 40
Refrigeration dryerULTRASEC 14
Activated carbon tower (ULTRAOX ST)ULTRAK 12
Oil/water separator (ULTRAOX ST)ULTRASEP 3
Air receiver2,000 L, 11.5 bar
Oxygen generatorULTRACON 11
Oxygen process tank1,000 L, 11.5 bar
Oxygen storage tank1,000 L, 11.5 bar

Tank pressures are maximum operating pressures.

For what each component does, see what equipment comes with each ULTRAOX model.

ULTRAOX SC or ULTRAOX ST

The 260 is listed in both versions. ULTRAOX SC uses oil-less ULTRACECO compressors and ULTRAOX ST uses ULTRASCREW screw compressors; see ULTRAOX SC and ULTRAOX ST, and the table of all 16 models in ULTRAOX models compared.

More questions

How many Nm³/h does the ULTRAOX 260 produce?

The 2026 ULTRAOX SC and ULTRAOX ST datasheets list 26.2 Nm³/h of oxygen at 93% ± 3% purity.

Does the ULTRAOX 260 change with altitude?

The tables list 26.2 Nm³/h at 0 to 1,000 m, 1,000 to 2,000 m and 2,000 to 3,000 m. In the ULTRAOX ST the compressor is ULTRASCREW 37, then ULTRASCREW 45, then ULTRASCREW 55.

How many oxygen generators does the ULTRAOX 260 use?

The tables list one ULTRACON 11 generator.

Sources

Ultra Controlo figures come from its technical datasheets. Third-party facts were read at the source on the date shown.

Reviewed: · Ultra Controlo engineering · Markdown version