Oxygen and PSA
ULTRAOX 1640: 165.3 Nm³/h PSA oxygen plant
According to the 2026 ULTRAOX SC and ULTRAOX ST datasheets, the ULTRAOX 1640 is the model with the highest oxygen flow in the table, 165.3 Nm³/h at 93% ± 3% purity, with two ULTRACON 15 generators and a maximum daily filling capacity of 528 cylinders (50 L at 150 bar).
In the model tables of the ULTRAOX SC and ULTRAOX ST datasheets, the 1640 is the last model, after the ULTRAOX 1120 (111.4 Nm³/h). The two tables list the same oxygen flow, daily filling capacity and oxygen generator for the two versions.
Datasheet values
| ULTRAOX 1640 | Value in the 2026 datasheets |
|---|---|
| Oxygen flow | 165.3 Nm³/h |
| Max. daily filling capacity | 528 cylinders (50 L at 150 bar) |
| Oxygen purity | 93% ± 3% |
| Oxygen generator | ULTRACON 15 × 2 |
| Layout | Simplex |
| Versions | ULTRAOX SC and ULTRAOX ST, the same flow in both |
The ULTRAOX product page describes its size match as indicative, from the datasheet, with Ultra Controlo engineers confirming the configuration for the site.
Compressor by altitude band
The ULTRAOX ST table lists an ULTRASCREW compressor for each altitude band: ULTRASCREW 250 at 0 to 1,000 m, ULTRASCREW 315 at 1,000 to 2,000 m and 2 × ULTRASCREW 160 at 2,000 to 3,000 m. The oxygen flow stays at 165.3 Nm³/h in all three bands. The notes add that at 2,000 to 3,000 m the ULTRAOX ST uses 2 oxygen filtration systems and 2 flow measurement systems.
The ULTRAOX SC table does not list the compressor of this model. Its notes say that at 2,000 to 3,000 m the ULTRAOX 1640 uses 2 compressors, 2 oxygen filtration systems and 2 flow measurement systems, and that compressor data for the other models is available on request.
The ULTRAOX ST datasheet states that the power and pressure of the compressor can vary with the service conditions required for the facility. Ultra Controlo engineering confirms the configuration for each project.
What the tables list with the ULTRAOX 1640
The components tables of the two datasheets list the following for this model. The ULTRAOX SC table has no column for the ULTRAK tower or the ULTRASEP separator.
| Component | Listed for the ULTRAOX 1640 |
|---|---|
| Aftercooler | ULTRACOOL 12 |
| Air treatment chain | CTA 80 |
| Refrigeration dryer | ULTRASEC 32 |
| Activated carbon tower (ULTRAOX ST) | ULTRAK 19 |
| Oil/water separator (ULTRAOX ST) | ULTRASEP 6 |
| Air receiver | 4 × 3,000 L, 11.5 bar |
| Oxygen generator | ULTRACON 15 × 2 |
| Oxygen process tank | 2,000 L, 11.5 bar |
| Oxygen storage tank | 2 × 2,000 L, 11.5 bar |
Tank pressures are maximum operating pressures. At 2,000 to 3,000 m the table notes add 2 oxygen filtration systems and 2 flow measurement systems.
For what each component does, see what equipment comes with each ULTRAOX model.
ULTRAOX SC or ULTRAOX ST
The 1640 is listed in both versions. ULTRAOX SC uses oil-less ULTRACECO compressors and ULTRAOX ST uses ULTRASCREW screw compressors; see ULTRAOX SC and ULTRAOX ST, and the table of all 16 models in ULTRAOX models compared.
More questions
How many Nm³/h does the ULTRAOX 1640 produce?
The 2026 ULTRAOX SC and ULTRAOX ST datasheets list 165.3 Nm³/h of oxygen at 93% ± 3% purity.
Does the ULTRAOX 1640 change with altitude?
The tables list 165.3 Nm³/h at 0 to 1,000 m, 1,000 to 2,000 m and 2,000 to 3,000 m. In the ULTRAOX ST the compressor is ULTRASCREW 250, then ULTRASCREW 315, then 2 × ULTRASCREW 160.
How many oxygen generators does the ULTRAOX 1640 use?
The tables list two ULTRACON 15 generators.
Sources
- ULTRAOX ST datasheet, 2026 edition (model and components tables, ULTRAOX 1640)
- ULTRAOX SC datasheet, 2026 edition (model and components tables, ULTRAOX 1640)